GE 60-960-95 installation instructions Power up the panel see “Powering Up the Panel”

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 20
Image 20
1.Power up the panel (see “Powering Up the Panel”).

Note

Regardless of supervised or unsupervised siren installa- tion, you must follow the order of installation as described to avoid learning the wrong (or undesired) House Code and SWS Supervision Code into siren memory.

Note

When installing Supervised Wireless Sirens for super- vised operation, be sure to program sensor text that clearly identifies each siren. For example, HALLWAY SIREN or BASEMENT SIREN. This can help both you and your customer locate a specific siren if a problem occurs.

￿For unsupervised wireless siren installations:

1.Power up the panel (see “Powering Up the Panel”).

2.Enter program mode and set the partition House Code to the desired setting (see the LIGHT CONTROL menu in the section “Programming the Panel”).

3.Exit program mode.

4.Install the siren backup battery.

5.Plug the siren into an electrical outlet.

6.Press the STATUS button on any working touchpad. The siren should beep once and the siren LED should flash 5 times, indicating it has learned the partition House Code.

7.If the siren doesn’t beep or the LED doesn’t flash, reset the house code on the siren by press- ing and holding its button for 20 seconds. The siren will beep three times when the memory has been cleared. Repeat step 6.

￿For supervised wireless siren installations:

1.Power up the panel (see “Powering Up the Panel”).

2.Install the siren backup battery.

3.Clear the siren memory by pressing and holding the siren button for 20 seconds. The siren will beep three times when the memory has been cleared.

4.Enter program mode and set the partition House Code to the desired setting (see the LIGHT CONTROL menu in the section “Programming the Panel”).

5.Proceed to the SIREN OPTIONS menu and set the SWS Supervision Code to the desired set- ting.

6.Proceed to the LEARN SENSORS menu and select the desired partition, sensor group 33, and the desired sensor number.

7.When the touchpad display shows TRIP SENSOR nn, plug the siren into an electrical outlet. The siren should beep once and the siren LED should flash 10 times, indicating the panel learned the siren transmitter ID and that the siren learned both the partition House Code and SWS Supervision Code.

8.Exit program mode.

Connecting an Interrogator 200 Audio Verification Module (60-677)

Connect the Interrogator 200 Audio Verification Module (AVM) to the panel terminals as shown in Figure 13. Partition 1 use only.

!speaker must be hooked up in series with that speaker to provide a 16-ohm load. Hook- ing up speakers in parallel to panel terminals 7 and 8 creates a 4-ohm load that canIf a speaker is already connected to panel terminals 7 and 8, the Interrogator 200

cause permanent damage to the panel.

Caution

Black

Yellow

Manual backgroundSplice

Run Separate Manual backgroundManual backgroundManual background

Wire Cables

As Shown

Manual backgroundCable Shield

Panel Terminals

7

8

4

3

11

 

Speaker

+12V

GND

MIC

Figure 13. Connecting an Interrogator 200 AVM to the Panel

15

Concord Ultra

Page 20
Image 20
GE 60-960-95 installation instructions Power up the panel see “Powering Up the Panel”