GE 60-960-95 Extended Delay partition 1: 0312, partition 2, 0323, Light Control Menu, 0410

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 43
Image 43
Extended Delay (partition 1: 0312, partition 2: 0322)

Extended Delay (partition 1: 0312, partition 2: 0322)

Timers-Partition 1-2 (Default = 4 min.)

 

 

This setting determines how much time the user has (after arming the system) to enter or exit the premises through a “designated extended delay door” (1–8 minutes).

Note

For UL Listed installations Extended Delay may not be used.

￿To set the Extended Delay:

1.With the display showing EXTENDED DELAY n MIN- UTES (current setting), enter the desired time value (1–8). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Siren Timeout (partition 1: 0313, partition 2:

 

Timers-Partition 1-2 (Default = 4 min.)

0323)

 

 

 

 

This setting determines how long sirens sound (1–30 min-

￿To set the Siren Timeout:

utes) if no one is present to disarm the system.

1.

With the display showing SIREN TIMEOUT nn MINUTES (cur-

Note

 

rent setting), enter the desired time value (1–30). The dis-

For UL Listed installations, the Siren Timeout must be set to 4

 

play flashes the entered setting.

minutes or more.

2.

Press # and the display show the new setting.

 

 

 

 

 

 

Sleep Time (partition 1: 0314, partition 2: 0324)

 

Timers-Partition 1-2 (Default = 22:00 [10:00 pm])

 

 

This setting determines the start time of a 10 hour window

￿To set the Sleep Time:

during which trouble beeps are suppressed. The initial occur-

1.

With the display showing SLEEP TIME hh:mm (current set-

rence of an event that causes trouble beeps within this win-

 

ting), enter the desired time value (00:00-23:50 using 10

dow will not sound trouble beeps until the Sleep Time

 

minute intervals). The display flashes the entered setting.

window expires. If trouble beeps from a previous event are

2.

Press # and the display show the new setting.

due to be restarted during the sleep time window, they will

￿To turn off Sleep Time:

be restarted one hour prior to Sleep Time.

Note

1.

With the display showing SLEEP TIME hh:mm (current set-

For UL listed installations, this feature must be set to off.

 

ting), press D.

 

 

 

Note

For light control to work, X10 Powerhouse Lamp Modules must be installed at desired lamps.

Light Control Menu

The LIGHT CONTROL menu lets you set up light activation for a specific partition.

The following describes how to program the light control settings that appear under PARTITION 1 and PARTITION 2.

Entry Lights (partition 1: 0400, partition 2:

 

Light Control-Partition 1-2 (Default = none)

0410)

 

 

 

 

This setting determines which X10 controlled lights turn on

￿To set the Entry Lights:

during entry and exit delays.

1.

With the desired partition selected, press #. The display

Note

2.

shows ENTRY LIGHTS nnnnnnn (current setting).

X10 Lamp Modules set to 1 always turn on during the entry and

Enter all the desired light numbers (3–9 based on the UNIT

exit delays.

 

dial setting on each X10 Lamp Module). The display

X10 Lamp Modules set to 2 always flash the arming level when

 

flashes the entered setting(s).

3.

Press # and the display shows the new setting(s).

arming the system. For example, lights flash two times when

 

 

arming to STAY (level 2), and three times when arming to AWAY

￿To delete Entry Lights:

(level 3).

1.

Enter any light number that appears on the display, then

 

 

 

press #. The number disappears from the display.

 

 

 

Concord Ultra

38

Page 43
Image 43
GE 60-960-95 Extended Delay partition 1: 0312, partition 2, Siren Timeout partition 1: 0313, partition, 0323, 0410