TP Panic RPT FMT (06009)

TP Panic RPT FMT (06009)

Reporting-Global (Default = off)

 

 

This setting determines how the panel formats touchpad panic alarm reports to the central station.

When this feature is turned on, touchpad panic alarms report using the following 3-digit codes:

Auxiliary—597, Police—598, Fire—599

When turned off, touchpad panic alarms report using a 3-digit code from 500 to 515, with the last digit identifying the touchpad device number.

￿To turn TP Panic RPT FMT off or on:

1.With the display showing TP PANIC RPT FMT OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

AC Failure (06010)

Reporting-Global (Default = off)

 

 

When this setting is on, the panel reports to the central station 15 min- utes after AC power to the panel is lost.

Note

For UL 1635 listed installations, this feature must be set to on.

￿To turn AC Failure reports off or on:

1.With the display showing AC FAILURE OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Receiver Failure (06011)

Reporting-Global (Default = off)

 

 

When this setting is on, the panel reports a receiver failure under the fol- lowing conditions:

No wireless sensor signals have been received for two hours or

The receiver is being jammed with a constant signal.

Note

For UL Listed installations using wireless devices, Receiver Failure must be set to on.

￿To turn Receiver Failure reports off or on:

1.With the display showing RECEIVER FAILURE OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new set- ting.

RF Low Bat Rpt (06012)

Reporting-Global (Default = weekly)

 

 

This setting determines whether the panel sends daily or weekly low battery reports to the central monitoring station when a wireless device is reporting a low battery condition to the panel.

￿To set RF Low Battery Report to daily or weekly:

1.With the display showing RF LOW BAT RPT DAILY/WEEKLY

(current setting), press 1 (daily) or 2 (weekly). The display flashes the entered setting.

2.Press # and the display shows the new setting.

RF Supv Rpt (06013)

 

Reporting-Global (Default = weekly)

 

 

This setting determines whether the panel sends daily or

￿To set RF Supv Report to daily or weekly:

weekly reports to the central monitoring station when the

1.

With the display showing RF SUPV REPORT DAILY/WEEKLY

panel detects a supervisory condition in a wireless device.

 

(current setting), press 1 (daily) or 2 (weekly). The display

 

 

flashes the entered setting.

 

2.

Press # and the display shows the new setting.

 

 

 