Next Phone Test (0303)

Next Phone Test (0303)

Timers-Global (Default = 7 days)

 

 

This setting is used by the Auto Phone Test feature (see PHONE OPTIONS—GLOBAL) to determine when the next automatic phone test should occur. This setting should be the same as, or less than, the Phone Test Freq. setting.

Note

For UL 1635 listed installations, this feature must be set to 1.

￿To set the Next Phone Test:

1.With the display showing NEXT PHONE TEST nnn DAYS (current setting), enter the number of days (1–255). The display flashes the entered setting.

2.Press # and the display shows the new setting.

 

Output Trip Time (0304)

 

 

Timers-Global (Default 4 sec.)

 

 

 

 

 

 

This setting determines how long outputs

￿To set the Output Trip Time:

 

are activated when tripped (if they are con-

1. With the display showing OUTPUT TRIP TIME nn SECS (current setting), enter

 

figured for a momentary response).

the number of seconds (1–12). The display flashes the entered setting.

 

 

2. Press # and the display shows the new setting.

 

 

 

 

 

 

 

 

 

 

 

Activity Timeout (0305)

 

 

Timers-Global (Default = 24 hours)

 

 

 

 

 

This setting determines when the system sends a “no

￿To set the Activity Timeout:

 

activity” report. The panel can be set to wait from 1–

1. With the display showing ACTIVITY TIMEOUT nn HOURS (current

 

42 hours. If no user interaction or device activation

setting), enter the number of hours (1–42). The display flashes the

 

occurs in that time, the panel sends a report to the

entered setting.

 

central station.

 

 

2. Press # and the display shows the new setting.

 

 

 

 

 

 

 

 

 

 

 

Daylight Saving (0306)

 

 

Timers-Global (Default = on)

 

 

 

 

 

When this setting is on, the panel clock automati- cally adjusts for daylight saving time changes.

￿To turn Daylight Saving off or on:

1.With the display showing DAYLIGHT SAVING OFF/ON (current set- ting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

The following sections describe the timer settings that appear under PARTITION 1-2.

Entry Delay (partition 1: 0310, partition 2: 0320)

 

Timers-Partition 1-2 (Default = 30 sec.)

 

 

This setting determines how much time the user has to dis-

￿To set the Entry Delay:

arm the system (after entering the armed premises through a

1.

With the display showing ENTRY DELAY nnn SECS (current

“designated delay door”) without causing an alarm.

 

setting), enter the desired time value (30–240 using 8-sec-

Note

2.

ond intervals). The display flashes the entered setting.

For residential UL Listed installations, the Entry Delay must be

Press # and the display shows the new setting.

set to 45 seconds or less. The combined time for the Entry Delay

 

 

and Dialer Abort Delay (02006) must not exceed 60 seconds.

 

 

 

 

 

 

 

 

Exit Delay (partition 1: 0311, partition 2: 0321)

 

Timers-Partition 1-2 (Default = 60 sec.)

 

 

 

This setting determines how much time the user has (after arming the system) to leave the premises through a “desig- nated delay door” without causing an alarm.

Note

For UL 1023 listed installations, this feature must be set to 60 seconds or less.

￿To set the Exit Delay:

1.With the display showing EXIT DELAY nnn SECS (current setting), enter the desired time value (45–184 using 8-sec- ond intervals). The display flashes the entered setting.

2.Press # and the display shows the new setting.

37

Concord Ultra

Page 42