Freeze Alarm (partition 1: 06107, partition 2: 06207)

Freeze Alarm (partition 1: 06107, partition 2: 06207)

Reporting-Partition 1-2 (Default = off)

 

 

This setting determines whether the panel reports a freeze alarm to the central station or pager, when the selected partition’s energy saver module detects a temperature that matches a predetermined setting (see BUS DEVICES—UNITID—ENERGYOPTIONS—FREEZE TEMP).

￿To turn Freeze Alarm reporting off or on:

1.With the desired partition selected, press A or B until the display shows FREEZE ALARM OFF/ON (current setting).

2.Press 1 (off) or 2 (on). The display flashes the entered setting.

3.Press # and the display shows the new setting.

Alarm Verify (partition 1: 06108, partition 2: 06208)

Reporting-Partition 1-2 (Default = off)

 

 

This setting determines whether the panel reports to the central monitoring station after a single sensor or zone trip (off) or waits for a second trip before reporting (on).

This setting affects sensors/zones in groups 10 through 20. If Alarm Verify is set to on, group 18 responds the same as group 17 (see “Appendix B, Table B1 “Sensor Group Characteristics”).

Note

For UL Listed installations, Alarm Verify must be set to off.

￿To turn Alarm Verify off or on:

1.With the display showing ALARM VERIFY OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

System Tamper (partition 1: 06109, partition 2: 06209)

Reporting-Partition 1-2 (Default = off)

 

 

This setting determines how the panel handles possible tamper situations. When this feature is on, the panel reacts in the following two ways:

The system goes into alarm if several attempts are made to disarm the system with incorrect access codes (40 consecutive keypresses).

The panel reports to the central station if a bus device stops communi- cating with the panel.

￿To change the System Tamper setting:

1.With the display showing SYSTEM TAMPER OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Siren Options Menu

The SIREN OPTIONS menu lets you set up siren operation and supervision.

The following describes how to program the siren option settings that appear under GLOBAL.

Immediate Beeps (0700)

Siren Options-Global (Default = off)

 

 

This setting determines whether the panel activates trouble beeps as soon as a wireless device supervisory condition is detected (on), or if the panel waits until “supervisory time” to activate trouble beeps (off). (Refer to

TIMERSGLOBALSUPERVISORY TIME).

Note

For UL Listed installations, this feature must be on.

￿To turn Immediate Beeps off or on:

1.With the display showing IMMEDIATE BEEPS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Disable Trouble Beeps (0701)

Siren Options-Global (Default = off)

 

 

When this setting is on, the panel will not beep to alert users of wireless device supervisory trouble.

Note

For UL Listed installations, Disable Trouble Beeps must be set to off.

￿To turn Disable Trouble Beeps off or on:

1.With the display showing DISABLE TR BEEPS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.