Arming (0660nn, where

Arming (0660nn, where

Attach Schedules To Events (Default = off)

nn=Schedule number [0 to 15])

 

 

 

This setting lets you arm according to a time schedule.

Note

This setting will allow you to arm to AWAY only. There is no disarm schedule.

￿To Attach Schedules to Arming:

1.Press A or B until the display shows ATTACH SCHEDULES TO EVENTS.

2.Press # then A or B until the display shows ARMING.

3.To select arm to AWAY press #.

4.Press # and the display shows SCHEDULE 00 OFF/ON (current setting). If you want a different schedule, press A or B until the desired schedule appears.

5.Press 1 (off) or 2 (on). The display flashes the entered selection.

6.Press # and the display shows the new setting for the selected schedule.

7.Repeat steps 4 and 5 until all desired schedules are attached.

Energy Saver Menu

The ENERGY SAVER menu lets you set the energy saver module low- and high-setpoints. These setpoints determine when the module relay closes, thereby completing the circuit through the thermostat to the furnace/air-conditioner.

Low Setpoint (070)

 

Energy Saver (Default = 50°F)

 

 

This setting determines the temperature at

￿To set the Low Setpoint:

which the energy saver module relay closes

1.

With the display showing ENERGY SAVER, press #, then A or B until the dis-

to activate the furnace.

 

play shows LOW SETPOINT NN DEGREES (current setting).

Note

2. Enter the desired temperature (45–89°). The display flashes the entered setting.

The low setpoint cannot be set equal to or

3.

Press # and the display shows the new setting.

higher than the high setpoint.

 

 

 

 

 

 

 

 

High Setpoint (071)

 

Energy Saver (Default = 90°F)

 

 

This setting determines the temperature at

￿To set the High Setpoint:

which the energy saver module relay closes

1.

With the display showing ENERGY SAVER, press #, then A or B until the dis-

to activate the air-conditioner.

 

play shows HIGH SETPOINT nn DEGREES (current setting).

Note

2. Enter the desired temperature (46–90°). The display flashes the entered setting.

The high setpoint cannot be set equal to or

3.

Press # and the display shows the new setting.

lower than the low setpoint.

Attach Lights to Sensors Menu

The ATTACH LIGHTS TO SENSORS menu lets you assign a light number to a sensor. Each time the sensor is activated, the attached light will turn on for 5 minutes. When the 5 minute timer expires the light will turn off. If the same light is scheduled, it will only turn on during the schedule time.

Lights X to Sensor Y (08n, where

Attach Lights To Sensors (Default = 0)

nn=light number [1 - 9] minus 1)

 

 

 

This menu attaches light x to sensor y. Each time a selected sensor is tripped, the selected light will turn on and a 5 minute timer will start.

Note

The sensor must be learned into the current partition before it can be attached.

￿To attach a light to a sensor:

1.With the display showing LIGHT 1 TO SENSOR y (current setting), press A or B to select the desired light number.

2.Enter the desired sensor number (01–96). The display flashes the entered setting.

3.Press # and the display shows the new setting.

4.Repeat steps 1 through 2 until all desired lights are attached to sensors.

￿To detach a light from a sensor:

1.With the display showing LIGHT 1 TO SENSOR y (current setting), press A or B to select the desired light number.

2.Enter 0 as the sensor number and press #.

Concord Ultra

62

Page 67
Image 67
GE 60-960-95 Arming 0660nn, where, nn=Schedule number 0 to, Low Setpoint, High Setpoint, Attach Lights to Sensors Menu