GE 60-960-95 Total System Wire Length Allowed, Minimum Device Current Draw, Max. Wire Length

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 12
Image 12
Table 2: Total System Wire Length Allowed

Table 1: Maximum Device Wire Length and Current Draw (Continued)

Device

Max. Wire Length

Max. mA

to Panel

Draw

 

 

 

 

8Z Hardwire Zone Expander SnapCard

N/A

230 mA*

 

 

 

4 Output SnapCard

N/A

130 mA*

 

 

 

SuperBus 2000 8Z Input Module

22 ga.—1,800 ft.

35 mA

18 ga.—4,000 ft.

 

 

 

 

 

SuperBus 2000 4-Relay Output Module

22 ga.—350 ft.

180 mA

18 ga.—900 ft.

 

 

 

 

 

SuperBus 2000 Energy Saver Module

22 ga.—1,600 ft.

20 mA

18 ga.—4,000 ft.

 

 

 

 

 

 

Standard Power:

 

 

22 ga.—15 ft.

1600 mA

SuperBus 2000 Cellular Backup Module

18 ga.—40 ft.

 

 

 

High Power

 

 

 

 

22 ga.—10 ft.

1900 mA

 

18 ga.—30 ft.

 

 

 

 

SuperBus 2000 Automation Module

22 ga.—1,500 ft.

35 mA

18 ga.—4,000 ft.

 

 

 

 

 

SuperBus 2000 Wireless Gateway Module

22 ga.—40 ft.

1600 mA

18 ga.—90 ft.

 

 

 

 

 

Interrogator 200

22 ga.—3,200 ft.

10 mA

18 ga.—4,500 ft.

 

 

 

 

 

Interrogator AVM

22 ga.—110 ft.

300 mA

18 ga.—260 ft.

 

 

 

 

 

*Maximum current draw for the SnapCards does not include the load which may be applied to their auxiliary DC supply.

Table 2 describes the total system wire lengths allowed when installing systems using unshielded or shielded cable.

Table 2: Total System Wire Length Allowed

Wire Type

Total System Wire

 

 

18-gauge, unshielded

4,500 ft.

18-gauge, shielded

3,000 ft.

 

 

22-gauge, unshielded

3,500 ft.

22-gauge, shielded

2,200 ft.

 

 

Table 3 describes the minimum current draw of each device when the panel is operating only from the backup battery. For 24-hour backup, the total current draw of all SnapCards connected to the panel and devices connected to +12V BUS (panel terminal 4) is limited to 190 mA (during normal standby condition) using a 7.0 AH battery.

Table 3: Minimum Device Current Draw

 

Device

Min. mA Draw

 

 

SuperBus 2000 2x16 LCD Alphanumeric Touchpad

15 mA

 

 

SuperBus 2000 2x20 LCD Alphanumeric Touchpad

15 mA

 

 

SuperBus 2000 2x20 VFD Alphanumeric Touchpad

15 mA

 

 

SuperBus 2000 Fixed Display Touchpad

11 mA

 

 

4 Input/2 Output SnapCard

20 mA

 

 

8Z Hardwire Zone Expander SnapCard

38 mA

 

 

4 Output SnapCard

1 mA

 

 

 

SuperBus 2000

8Z Input Module

18 mA

 

 

 

SuperBus 2000

4-Relay Output Module

12 mA

 

 

 

SuperBus 2000

Energy Saver Module

20 mA

 

 

 

SuperBus 2000

Cellular Backup Module

90 mA

 

 

 

7

Concord Ultra

Page 12
Image 12
GE 60-960-95 Total System Wire Length Allowed, Minimum Device Current Draw, Max. Wire Length, Max. mA, to Panel, Wire Type