GE 60-960-95 No Activity partition 1: 06103, partition 2, Reporting-Partition 1-2Default = off

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 49
Image 49
No Activity (partition 1: 06103, partition 2: 06203)

No Activity (partition 1: 06103, partition 2: 06203)

 

Reporting-Partition 1-2 (Default = off)

 

 

When this setting is on, the panel sends a no activity report to the central

￿To turn No Activity reports off or on:

station when the activity timeout expires (see TIMERS—ACTIVITY TIMEOUT).

1.

With the display showing NO ACTIVITY OFF/

 

 

ON (current setting), press 1 (off) or 2 (on).

 

 

The display flashes the entered setting.

 

2.

Press # and the display shows the new setting.

 

 

 

 

 

 

Duress Option (partition 1: 06104, partition 2: 06204)

 

Reporting-Partition 1-2 (Default = off)

 

 

When this setting is on, the system can be controlled using a programmed

￿To turn Duress Option off or on:

duress code (see SECURITY—PARTITION N—DURESS CODE).

1.

With the display showing DURESS OFF/ON

Note

 

(current setting), press 1 (off) or 2 (on). The

For UL Listed installations, Duress Option must be set to off.

 

display flashes the entered setting.

Do not use a duress code unless it is absolutely necessary. Using duress

2.

Press # and the display shows the new setting.

 

 

codes often results in false alarms due to code entry errors. If a duress

 

 

code is absolutely necessary, use it with the audio verification module to

 

 

reduce false alarms and accidental dispatches.

 

 

 

 

 

 

 

 

Forced Armed (partition 1: 06105, partition 2: 06205)

 

Reporting-Partition 1-2 (Default = off)

 

 

 

When this setting is on, the panel reports to the central monitoring station when a user “force arms” the system.

Note

Forced arming occurs if the user presses BYPASS when arming the system with open sensors or zones protesting.

Auto-forced arming occurs if the user does not press BYPASS (when arming the system with open sensors/zones protesting) and the siren time expires.

Auto-forced arming always reports to the central monitoring station.

￿To turn Force Armed off or on:

1.With the display showing FORCE ARMED OFF/ ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Latchkey Format (partition 1: 06106, partition 2: 06206)

Reporting-Partition 1-2 (Default = off)

 

 

This setting determines whether the selected partition is set up for basic (off) or advanced (on) latchkey opening report operation.

Basic:

If the partition is armed by entering 2 (or 3) + CODE, disarming using a designated latchkey user code or keychain touchpad within an assigned time schedule sends a page.

If the partition is armed by entering 2 (or 3) + CODE + 6 (Latchkey), dis- arming using a designated latchkey user code or keychain touchpad inside or outside of an assigned time schedule sends a page.

Advanced:

If the partition is armed by entering 2 (or 3) + CODE + 6 (Latchkey), dis- arming using a latchkey designated user code or keychain touchpad within an assigned time schedule sends a page.

Refer to the User’s Guide for complete Latchkey setup and operation.

￿To turn Latchkey Format off or on:

1.With the desired partition selected, press A or B until the display shows LATCHKEY FORMAT OFF/ON (current setting).

2.Press 1 (off—basic) or 2 (on—advanced). The display flashes the entered setting.

3.Press # and the display shows the new setting.

Concord Ultra

44

Page 49
Image 49
GE 60-960-95 No Activity partition 1: 06103, partition 2, Duress Option partition 1: 06104, partition 2, Basic, Advanced