GE 60-960-95 installation instructions Connecting the AC Power Transformer

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 25
Image 25
Connecting the AC Power Transformer

Note

Connecting the panel to an analog line off the phone switch places the panel ahead of the phone system, preventing panel access from phones on the pre- mises. However, the panel can still be accessed from off-site phones.

If an analog line is not available, contact a telecommunications specialist and request an ana- log line off the phone switch (PBX mainframe) or a 1FB (standard business line).

￿To connect a phone line to the panel using an RJ-31X/CA-38A jack (see Figure 23):

1.Run a 4-conductor cable from the TELCO protector block to the jack location.

2.Connect one end of the cable to the jack (see B in Figure 34).

3.At the TELCO protector block, remove the premises phone lines from the block and splice them to the black and white (or yellow) wires of the 4-conductor cable (see C in Figure 34).

4.Connect the green and red wires from the 4-conductor cable to the TIP (+) and RING (-) posts on the block (see D in Figure 34).

5.Check the phones on the premises for dial tone and the ability to dial out and make phone calls. If phones do not work correctly, check all wiring and correct where necessary. Proceed to the “Troubleshooting” section of this manual if problems persist.

 

Brn

 

Gry

 

 

 

RJ-31X

 

 

 

Jack

 

White (or Yellow)

 

Grn

 

Red

Black

Green

B

Red

 

TELCO

 

A

Protector Block

RJ-31X

 

 

 

TIP

RING

 

Phone

(+)

(-)

 

 

Line

 

 

 

D

Red

Wire

Run

Green

 

 

Black C White (or Yellow)

Green

Red

 

 

 

Lines From

 

 

 

 

 

 

Phones On

 

 

 

Premises

Figure 23. Installing an RJ-31X Phone Jack

Connecting the AC Power Transformer

The panel must be powered with the Line Carrier Power Transformer that supplies 24 VAC, 50 VA (60-779). Connect the power transformer to the panel as shown in Figure 24.

!Do not plug in the power transformer at this time. The panel must be powered up using the sequence of steps described in the next section, “Powering Up the Panel.”

Caution

Panel Terminals

Manual background 24VACManual background

1

2

 

 

Backup Battery Connections

 

Black

Red

 

 

f

Black

Red

 

Battery

Figure 24. Connecting a Power Transformer and Backup Battery to the Panel

Concord Ultra

20

Page 25
Image 25
GE 60-960-95 installation instructions Connecting the AC Power Transformer