Audio Verification Menu

Audio Verification Menu

The AUDIO VERIFICATION menu lets you set up the audio verification module (AVM) operation in partition 1. If you want audio verification for partition 2, you must install a “stand-alone” audio verification module and a 4-Relay Output Module (HOM) (60-770) output for that partition.

The following sections describe the audio verification settings that appear under PARTITION 1.

Audio Verify (0900)

Audio Verification-Partition 1 (Default = off)

 

 

This setting determines whether or not the system can be accessed by phone for alarm verification.

￿To turn Audio Verification off or on:

1.With the display showing AUDIO VERIFICATION, press #. The display shows PARTITION 1.

2.Press # again and the display shows AUDIO VERIFY OFF/ON (current setting).

3.Press 1 (off) or 2 (on). The display flashes the entered setting.

4.Press # and the display shows the new setting.

Audio Mode (0901)

Audio Verification-Partition 1 (Default = 1)

 

 

This setting determines how the audio verification module operates. Choose one of the following:

(1) Instant—Allows the central station operator instant access for an audio session by entering the AVM code or by pressing * (if an AVM access code is not programmed) upon completion of panel alarm report (also see ACCESS TIMEOUT).

(2) Callback—Allows the central station operator to contact persons on the premises after one ring and verify the alarm report. Operator must press * or enter the AVM access code within 20 seconds after ring. The panel does not report any alarms during the AVM session, except for fire alarms.

(3) Callback Silent—Same as Callback, except premises phones do not ring.

￿To set Audio Mode:

1.With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows AUDIO MODE nn (current setting).

2.Enter the desired mode number (1–3). The display flashes the entered setting.

3.Press # and the display shows the new set- ting.

Fire Shutdown (0902)

Audio Verification-Partition 1 (Default = off)

 

 

This setting determines whether system sirens turn off during a fire alarm audio session.

￿To turn Fire Shutdown off or on:

1.With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows FIRE SHUTDOWN OFF/ON (current setting).

2.Press 1 (off) or 2 (on). The display flashes the entered setting.

3.Press # and the display shows the new setting.

Silent Talkback (0903)

Audio Verification-Partition 1 (Default = off)

 

 

This setting determines whether the central station operator can speak to persons on the premises (on) or only listen (off) during a silent or duress alarm audio session.

￿To turn Silent Talkback off or on:

1.With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows SILENT TALKBACK OFF/ON (current setting).

2.Press 1 (off) or 2 (on). The display flashes the entered setting.

3.Press # and the display shows the new setting.

Access Timeout (0904)

Audio Verification-Partition 1 (Default = 90 sec.)

 

 

If the Audio Mode is set to “Instant,” then this set- ting determines how much time (30–300s, in 2-sec- ond increments) the central station operator has to enter the AVM access code after the panel is accessed for an audio session.

￿To change the Access Timeout:

1.With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows ACCESS TIMEOUT nn SECS (current setting).

2.Enter the desired time. The display flashes the entered setting.

3.Press # and the display shows the new setting.

49

Concord Ultra

Page 54
Image 54
GE 60-960-95 Audio Verification Menu, Audio Verify, Audio Mode, Fire Shutdown, Silent Talkback, Access Timeout