Exception Rpts (cs phone 1: 0103, cs phone 2: 0113, cs phone

Phones-CS Phone 1-3 (Default = off)

3: 0123)

 

 

 

When this setting is on, the panel reports to the central station if the system is not armed or disarmed at the specified schedule times.

￿To turn Exception Reports off or on:

1.With the display showing EXCEPTION RPTS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Open/Close Rpts (cs phone 1: 0104, cs phone 2: 0114, cs

Phones-CS Phone 1-3 (Default = off)

phone 3: 0124)

 

 

 

This setting determines whether opening and closing reports are sent to the cen- tral station. When turned on, the panel sends a closing report when the system is armed and an opening report when the system is disarmed.

Note

To use this feature, the Opening Reports and Closing Reports settings under the REPORTING menu must be turned on for that partition.

￿To turn Opening/Closing Reports off or on:

1.With the display showing OPEN/CLOSE RPTS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Backup (cs phone 1: 0105, cs phone 2: 0115, cs phone 3: 0125)

Phones-CS Phone 1-3 (Defaults: CS Phone 1 = on, CS Phone 2&3 = off)

This setting determines whether or not the panel uses another programmed cen- tral station phone number for reporting if attempts with the first number are unsuccessful.

When Back Up is off, the panel will make up to eight attempts to deliver a report with the programmed phone number.

When Back Up is set to on, the panel makes up to 16 attempts to deliver the report, alternating between the programmed phone number and the backup phone number.

CS PHONE 1 is backed up by CS PHONE 2.

CS PHONE 2 is backed up by CS PHONE 1.

CS PHONE 3 is backed up by CS PHONE 1.

￿To turn Backup off or on:

1.With the display showing BACK UP OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

SIA/CID Reporting (cs phone 1: 0106, cs phone 2: 0116, cs

Phones-CS Phone 1-3 (Default = CID)

phone 3: 0126)

 

 

 

This setting determines whether the panel uses the SIA or CID (Contact ID) reporting format for central station communication.

￿To select SIA or CID reporting:

1.With the display showing REPORTING FORMAT SIA/CID (current setting), press 1 (for SIA) or 2 (for CID). The display flashes the entered setting.

2.Press # and the display shows the new setting.