GE 60-960-95 Keychain TP Arm partition 1: 0513, partition 2, Reporting Menu, HourTamper

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 45
Image 45
Keychain TP Arm (partition 1: 0513, partition 2: 0523)

Keychain TP Arm (partition 1: 0513, partition 2: 0523)

Touchpad Options-Partition 1-2 (Default = off)

When this setting is on, pressing the lock button on keychain touchpads arms the system directly to AWAY with NO DELAY.

When this setting is off, each key-press increments the arming level (i.e., from OFF to STAY, from STAY to AWAY).

￿To change the Keychain Touchpad Arming setting:

1.With the display showing KEYCHAIN TP ARM OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Star Is No Delay (partition 1: 0514, partition 2: 0524)

Touchpad Options-Partition 1-2 (Default = off)

 

 

This setting determines whether the keychain touchpad star button controls an output (off) or the No Delay feature (on).

￿To change the keychain Star Is No Delay setting:

1.With the display showing STAR IS NO DELAY OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Reporting Menu

The REPORTING menu lets you set up which system events are reported to the central monitoring station. The following describes how to program the reporting settings that appear under GLOBAL.

24-Hour Tamper (06000)

Reporting-Global (Default = off)

 

 

When this setting is on, the panel sounds sirens and reports a tamper alarm (even when the system is disarmed), when wireless sensor tamper switches are activated.

￿To turn 24-Hour Tamper off or on:

1.With the display showing 24 HOUR TAMPER OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Buffer Control (06001)

 

Reporting-Global (Default = off)

 

 

When this setting is on, only arming level changes are logged in

￿To turn Buffer Control off or on:

the buffer (memory) of the panel. When this setting is off, all sys-

1.

With the display showing BUFFER CONTROL OFF/ON

tem events are logged in the buffer.

 

(current setting), press 1 (off) or 2 (on). The display

 

 

flashes the entered setting.

 

2.

Press # and the display shows the new setting.

 

 

 

 

 

 

Back In Service (06002)

 

Reporting-Global (Default = on)

 

 

 

When this setting is on, the panel reports to the central station when AC and backup battery power are restored (after an extended power outage).

￿To turn Back In Service reports off or on:

1.With the display showing BACK IN SERVICE OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Bypass Reports (06003)

Reporting-Global (Default = off)

 

 

When this setting is on, the panel reports to the central station whenever sensors or zones are bypassed.

￿To turn Bypass Reports off or on:

1.With the display showing BYPASS REPORTS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Concord Ultra

40

Page 45
Image 45
GE 60-960-95 Keychain TP Arm partition 1: 0513, partition 2, Star Is No Delay partition 1: 0514, partition 2, HourTamper