Dealer Code (0002)

 

Dealer Code (0002)

 

 

Security-Global (Default = none)

 

 

 

 

 

The 4-digit dealer code is used to prevent unauthorized persons

￿To program a Dealer Code:

 

from changing the programmed central station phone numbers.

1.

With the display showing DEALER CODE ****, enter the

 

When this feature is enabled, central station phone numbers

 

desired 4-digit code. The display flashes the entered

 

cannot be changed (unless you enter the program mode by

 

code.

 

using the dealer code). All other system settings are still acces-

2.

Press # and the display shows the new code.

 

sible by entering the program mode with the installer code.

￿To delete a Dealer Code:

 

Note

 

1.

With the display showing DEALER CODE nnnn (current

 

The Dealer Code cannot be deleted by clearing panel memory.

 

 

 

code), press D. The display shows DEALER CODE ****.

 

 

 

 

 

 

 

 

 

 

 

Access Code Lock (0003)

 

 

Security-Global (Default = on)

 

 

 

 

 

This setting determines whether or not the panel will include Access Codes when sending user information to the automation module. When this option is on, it means the Access Codes are not sent.

￿To turn Access Code Lock off or on:

1.With the display showing ACCESS CODE LOCK ON/OFF, press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

SIA False Alarm Reduction (0004)

Security-Global (Default = on)

 

 

Controls the following settings that are required by the SIA False Alarm Reduction Standard:

Arming level changes made from wireless touchpads and keychain touchpads are sounded (beeps) on exterior siren output (on) OR are not sounded on exte- rior siren output (off).

Note

The siren output must be configured for “Exterior Siren” (016xx) and on the two onboard outputs and SnapCard outputs only, for the arming level beeps to be annunciated.

To turn SIA False Alarm Reduction off or on:

1.With the display showing SIA FALSE ALARM (current setting), press 1

(off) or 2 (on). The display flashes the entered setting.

2.Press ƒ and the display shows the new setting.

The Arming Always Silent feature is disabled for users if this setting is on OR can be controlled by users if the setting is off. Silent Arming on Demand is not affected.

The following sections describe the security settings that appear under PARTITION 1 and 2.

Account Number (partition 1: 0010, partition 2: 0020)

Security-Partition 1-2 (Default = 00000)

 

 

The account number is used as panel (or customer) identification for the central monitoring station. The panel sends the account number every time it reports to the central station. Account numbers must be 1 to 10 characters long.

Alpha characters A–F can be assigned to the account number by pressing and holding buttons 1–6 respectively, until the character appears.

￿To program an Account Number:

1.With the display showing ACCOUNT NUMBER nnnnn (current number), enter the desired account number. The display flashes the entered number.

2.Press # and the display shows the new number.

Quick Arm (partition 1: 0011, partition 2: 0021)

Security-Partition 1-2 (Default = off)

 

 

Quick Arm allows system arming without using an access code. When Quick Arm is on, the system arming level can be increased from Level 1- OFF to LEVEL 2-STAY, from Level 1-OFF to LEVEL 3-AWAY, or from Level 2-STAY to LEVEL 3-AWAY, without entering an access code.

A valid access code is still required to decrease the arming level or disarm the system.

￿To turn Quick Arm off or on:

1.With the display showing QUICK ARM OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

25