Figure 21. Connecting the SuperBus to the Panel

Automation Module Circuit Board

DB-9 Serial Cable

123456

ZCOM

ZONE1

GND

+12V

A BUS B

Panel

3

4

5

6

Terminals

Automation Device

Figure 21. Connecting the SuperBus to the Panel

SuperBus 2000 Wireless Gateway Module (60-861)

Connect the SuperBus 2000 Wireless Gateway Module to the panel as shown in Figure 22.

+12V A B GND Z1 ZCOM

Module Wiring Terminals Setting Device Address on SuperBus 2000 DevicesInstalling an RJ-31X Phone Jack (13-081)Manual backgroundManual background

Panel Terminals

3

4

GND +12V

5

6

A BUS B

UL-Listed

Normally

Closed (N/C)

Contacts

in Series

OR

UL-Listed

Normally

Open (N/C)

Contacts

in Parallel

Note

The panel cannot be used on a digital or PBX phone line. These systems are designed for digital type devices only, operating any- where from 5 volts DC and up. The panel uses an ana- log modem and does not have a digital converter, adapter, or interface to oper- ate through such systems.

2.0K Ohm EOL Resistor 01-022

(Install at Last Contact)

Figure 22. Connecting the Wireless Gateway Module to the Panel

Setting Device Address on SuperBus 2000 Devices

When the panel is powered up it automatically assigns device addresses and unit numbers to SuperBus 2000 devices, enabling the panel and module to communicate.

Installing an RJ-31X Phone Jack (13-081)

Use the following guidelines when installing an RJ-31X phone jack for system control by phone and central station monitoring.

Locate the RJ-31X jack (CA-38A in Canada) no further than five feet from the panel.

The panel must be connected to a standard analog (loop-start) phone line, that provides 48 volts DC (on-hook or idle) which increases to 89 to 105 volts DC (ring voltage).

For full line seizure, install an RJ-31X phone jack on the premises phone line so the panel is ahead of all phones and other devices on the line. This allows the panel to take control of the phone line when an alarm occurs, even if the phone is in use or off-hook.