GE 60-960-95 Device ID, Partition Assign, Output Programming, Status Beeps, ting

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 56
Image 56
Device ID

Device ID

Acc. Modules-Bus Devices-Unit ID-Change ID (Default = none)

 

 

This menu lets you change the bus device ID number when replacing a defective bus device.

￿To change a Device ID:

1.With the display showing the desired bus device, press # + #. The display shows DEVICE ID (current ID).

2.Enter the ID of the new bus device. The display flashes the entered selection. Press # and the display shows the new setting.

3.Exit programming mode.

4.Remove AC and battery power from the panel.

5.Replace the defective bus device with a new one.

6.Apply AC and battery power to the panel.

Partition Assign

Acc. Modules-Bus Devices-Unit ID-Device Partition (Default = 1)

 

 

This menu lets you assign bus devices to work in the desired partition.

Note

SuperBus 2000 8Z Input Modules, SuperBus 2000 4-Relay Output Mod- ules, and SuperBus 2000 RF Receivers are not assigned to partitions.

￿To assign bus devices to partitions:

1.With the display showing the desired bus device, press #.

2.Press A or B until the display shows DEVICE PTN and then press #. The display shows PARTITION ASSIGN n.

3.Press 1 or 2 to select the desired partition. The display flashes the entered selection.

4.Press # and the display shows the new setting.

Output Programming

 

Acc. Modules--Unit ID-Outputs

 

 

Use these settings to program the output points of

￿To program each of the HOM output point configurations into the

any installed SuperBus 2000 Hardwire Output Mod-

 

security panel. The point configuration number is tttrr, where ttt is

ule. The installer programs a HOM output point into

 

the trigger number and rr is the response number.

1.

With the display showing the desired bus device, press #.

the Concord Ultra security panel by entering three

kinds of information.

2.

Press A or B until the display shows OUTPUTS.

Partition -the system partition (1 or 2).

3.

Press #. The display shows OUTPUT 1.

4.

Press A or B to select an output, then press #. The display shows

Trigger - the event that activates the output

 

PARTITION ASSIGN 1.

point. Trigger events can be partition alarms,

5.

Press 1 or 2 to select the desired partition assignment for this relay.

trouble conditions, open sensors, etc. (see

 

The display flashes the entered setting. Press # and the display

Appendix B: Reference Tables).

 

shows the new setting.

Response - how the output responds when trig- 6. Press A or B. The display shows CONFIGURATION tttrr (current set-

 

ger event occurs (see Appendix B: Reference

 

ting).

 

Tables).

7. Enter the desired 5-digit configuration number for this relay. The

 

Note

 

display flashes the entered setting. Press # and the display shows the

 

HOM output points cannot be configured for user con-

 

new setting.

 

trol. Only the onboard and SnapCard outputs can be

8. Press # and repeat steps 4 through 8 until all outputs are pro-

 

configured for user control.

 

grammed

 

 

 

 

 

 

 

Status Beeps

Acc. Modules--Bus Device-Unit ID-Keypad Options (Default = on)

 

 

 

 

This setting determines whether or not the selected

￿To turn touchpad Status Beeps on or off:

 

touchpad sounds status beeps. Each touchpad can be

1.

With the display showing the desired touchpad, press # then A or B

 

set individually.

 

until the display shows KEYPAD OPTIONS.

 

This feature is usually turned off for a touchpad that

2.

Press # and the display shows STATUS BEEPS OFF/ON (current set-

 

is located in or near bedrooms, to avoid disturbing

 

ting).

 

sleeping persons.

3.

Press 1 (off) or 2 (on) to select the desired setting. The display

 

Note

 

flashes the entered selection.

 

4.

Press # and the display shows the new setting.

 

For UL Listed installations, Status Beeps must be set to

on.

51

Concord Ultra

Page 56
Image 56
GE 60-960-95 Device ID, Partition Assign, Output Programming, Status Beeps, Acc. Modules--Unit ID-Outputs, ting