Hardwire Interior Speaker (60-528)

Hardwire Interior Speaker (60-528)

For interior siren applications. Connect the speaker to the panel as shown in Figure 9.

!Connect only the large speaker to the panel terminals 7 and 8 as shown. The smaller speaker cannot handle to output of terminals 7 and 8. To avoid damaging the speaker, the smaller speaker should not be connected to terminals 7 and 8.

Caution

Connect two units to the panel terminals with speakers in series (16-ohms), as shown in Figure 10.

Exterior

SpeakerSpeaker

7

8

7

8

Splice Connecting Piezo Sirens

2 8-Ohm Speakers in

Series (16 Ohms)

 

Interior

 

Speaker

 

Not Used

7

8

Panel

Terminals

Figure 9. Wiring Speakers

Not Used

Panel

Not Used

Terminals

Speaker

 

Figure 10. Wiring Two Hardwire Interior Speakers w/Dual Speaker Units to Panel Terminals

Connecting Piezo Sirens

Output 1

Onboard output 1 (OUT 1—terminal 9) is an open-collector (switched path-to-ground), program- mable output that can handle a maximum of 200 mA current sink. The default setting (01614) activates the output 15 seconds after a police or fire alarm condition occurs. This allows you to connect a piezo siren without changing the output configuration number in programming. This output is typically used for exterior siren application.

Output 2

Onboard output 2 (OUT 2—terminal 10) is an open-collector (switched path-to-ground), pro- grammable output that can handle a maximum of 200 mA current sink. The default setting