Sensor Text (081)

Table 8: Onboard Hardwire Zone Factory Programming

Zone Input

Group No. & Description

613–Instant Perimeter

713–Instant Perimeter

813–Instant Perimeter

Note

If the panel memory is cleared, all onboard hardwire zone factory programming will be erased.

 

Sensor Text (081)

 

 

 

Sensors (Default = none)

 

 

 

 

 

 

Use the following guidelines to “name” zone and sensor loca-

 

￿To program Sensor Text:

 

tions:

 

 

1. Press A or B until the display shows SENSOR TEXT.

 

• Use the item numbers that appear in Appendix B, Table B2

 

2. Press # and the display shows TEXT FOR SN 01.

 

“Item Numbers and Sensor Text” for characters and words

 

3. Press A or B until the display shows the desired sensor

 

listed there.

 

 

 

number (or enter the desired sensor number and press

 

• If a desired word does not appear in Table B2, create it

 

 

 

#).

 

 

4.

Press # and the display shows: SN 1 ITEM 0 0 - ________.

 

using the characters (custom text).

 

 

 

 

 

Where ITEM 0 is the first character/word location and 0

 

• When using words from Table B2, spaces between them

 

 

 

 

 

is the character/word number.

 

appear automatically. When using characters from Table B2

 

 

 

5.

Enter the number of the desired character or word, or

 

to create words, you must reserve an item number for a

 

 

 

scroll through the numbers by pressing B (forward) or

 

‘space’ after the word.

 

 

 

 

 

 

 

A (backward). If you make a mistake, simply enter the

 

• Each character or word uses up one item number. For exam-

 

correct number or continue scrolling through choices.

 

ple, a word from the list counts as one item number. A cre-

 

6. Press # to accept the displayed choice and the display

 

ated word (such as BOY’S) counts as six item numbers—4

 

 

shows: SN 1 ITEM 1 0 -.

 

letters, 1 apostrophe, and 1 space.

 

 

7. Repeat steps 5 and 6 as needed to complete the zone or

 

• Only 16 item numbers are allowed for each zone or sensor

 

 

sensor name.

 

name, so plan ahead before programming sensor text. You

 

8. Press * after entering the last character or word num-

 

may need to abbreviate words to avoid running out of item

 

 

ber. The display shows the complete text name. For

 

numbers.

 

 

 

example: TEXT FOR SN 01 FRONT ENTRY DOOR.

 

 

 

 

 

 

 

 

 

 

 

 

 

Delete Sensors (082)

 

 

 

Sensors (Default = none)

 

 

 

 

The following procedure describes how to remove hard-

￿To Delete Sensors from panel memory:

 

wire zone and wireless sensor numbers from panel mem-

1.

Press A or B until the display shows DELETE SENSORS.

 

ory.

2.

Press # and the display shows DELETE SENSOR nn (lowest

 

Note

3.

zone/sensor number in panel memory).

 

Deleting sensors does not delete sensor text associated with

Press # to delete the displayed sensor or—enter the desired

 

the deleted sensor number. To delete sensor text, enter the

 

sensor number, then press #.

 

SENSOR TEXT menu and enter 000 (nulls) for each item number.

4.

Repeat steps 2 and 3 until all desired sensors are deleted.

 

 

 

 

 

 

 

 

 

 

 

 

 

Edit Sensors (083)

 

 

 

Sensors (Default = none)

 

 

 

 

This menu lets you view and, if desired, change the group

￿To Edit Sensors:

 

and partition assignment for each learned zone or sensor.

1.

Press A or B until the display shows EDIT SENSORS.

 

For example, the display shows: S01 P1 G13 NC HW BACK

2.

Press # and the display shows the sensor or zone with the low-

 

DOOR. Where: S01 = zone/sensor number, P1 = partition 1,

 

est number.

 

G13 = sensor group 13, NC = normally closed, HW = hard-

3.

Press A or B to scroll through all learned zones and sensors.

 

wired, and BACK DOOR is the programmed text name.

4.

When the desired zone or sensor is displayed, press #. The

 

Other description codes include, RF = wireless sensor, TP =

 

display shows SENSOR PTN n

 

touchpad, NO = normally open.

5.

(current partition assignment).

 

 

Enter the desired partition number, then press #. The display

 

 

 

shows the new partition assignment.

 

 

6.

Press A or B and the display shows SENSOR GROUP nn (cur-

 

 

 

rent group assignment).

 

 

7.

Enter the desired group number, then press #. The display

 

 

 

shows the new group assignment.

 

 

 

 

 

 

Concord Ultra

48

Page 53
Image 53
GE 60-960-95 Sensor Text, Delete Sensors, Edit Sensors, Sensors Default = none, zone/sensor number in panel memory