Quick Exit (partition 1: 0012, partition 2: 0022)
STAY ARMING OFF/ON

Quick Exit (partition 1: 0012, partition 2: 0022)

Security-Partition 1-2 (Default = on)

 

 

This setting determines whether or not users can open and close a standard entry/exit door without causing an alarm (while the system is armed).

This feature would be useful if the user wants to go out to get the morning paper while the system is armed. This feature also allows the user to leave the armed pre- mises without having to disarm and re-arm the system.

When Quick Exit is on, pressing D on a touchpad (while the system is armed) starts a 2-minute timer that allows one standard entry/exit door (sensor groups 10 and 19 only) to be activated once (opened, then closed).

When this feature is off, the system must be disarmed before any protected door is opened.

Note

For UL Listed installations, this feature must be set to off.

￿To turn Quick Exit off or on:

1.With the display showing QUICK EXIT OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Exit Extension (partition 1: 0013, partition 2: 0023)

Security-Partition 1-2 (Default = on)

 

 

This setting determines whether or not the user can re-enter and exit again through an entry or exit delay door (without disarming and re-arming the system). This helps pre- vent exit faults and false alarms by allowing users to re-enter the premises for a forgot- ten item.

When Exit Extension is on, the panel restarts the exit delay timer if the user re-enters the premises through a standard delay door before the standard exit delay time expires.

When this feature is off, the exit delay timer does not restart if the user re-enters the premises, forcing the user to disarm the system to avoid setting off an accidental alarm.

￿To turn Exit Extension off or on:

1.With the display showing EXIT

EXTENSION OFF/ON (current set- ting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Auto Stay Arming (partition 1: 0014, partition 2: 0024)

Security-Partition 1-2 (Default = on)

 

 

This setting determines whether or not the system automatically arms to STAY (level 2) if the user arms the system to AWAY (level 3) without exiting the premises. This can help prevent accidental alarms by deactivating interior motion sensors dur- ing occupied arming periods.

Note

Arming the system to “AWAY with No Delay” overrides the Auto Stay Arming feature.

When this feature is on and the system is armed to AWAY, touchpads (and other sta- tus sounders) emit one exit delay beep every four seconds, then one every second during the last 10 seconds. If the exit delay time expires with no standard delay sen- sor activation, the system automatically arms to STAY.

￿To turn Auto Stay Arming off or on:

1.With the display showing AUTO

(current set-

ting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Concord Ultra

26

Page 31
Image 31
GE 60-960-95 Quick Exit partition 1: 0012, partition 2, Exit Extension partition 1: 0013, partition 2, current set