GE 60-960-95 installation instructions Appendix B Reference Tables

Models: 60-960-95

1 104
Download 104 pages 42.3 Kb
Page 87
Image 87
Appendix B:

Appendix B:

Reference

Tables

Table B1: Sensor Group Characteristics

No.

Name

Application

Alarm

Delay

Restoral

Supervisory

ReportCS

(LevelChime1)

ActiveLevels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

Fixed Panic

24-hour audible fixed emergency buttons.

Police

Instant

 

 

1, 2, 3

 

 

 

 

 

 

 

 

 

 

01

Portable Panic

24-hour audible portable emergency buttons.

Police

Instant

 

 

 

1, 2, 3

 

 

 

 

 

 

 

 

 

 

02

Fixed Panic

24-hour silent fixed emergency buttons.

Silent

Instant

 

 

1, 2, 3

 

 

 

 

 

 

 

 

 

 

03

Portable Panic

24-hour silent portable emergency buttons.

Silent

Instant

 

 

 

1, 2, 3

 

 

 

 

 

 

 

 

 

 

04

Fixed Auxiliary

24-hour auxiliary sensor, such as Pendant Panic or

Auxiliary

Instant

 

 

1, 2, 3

 

 

holdup button.

 

 

 

 

 

 

 

05

Fixed Auxiliary

24-hour auxiliary emergency button. Siren shutoff con-

Auxiliary

Instant

 

 

1, 2, 3

 

 

firms CS report.

 

 

 

 

 

 

 

06

Portable Auxiliary

24-hour portable auxiliary alert button.

Auxiliary

Instant

 

 

 

1, 2, 3

 

 

 

 

 

 

 

 

 

 

07

Portable Auxiliary

24-hour portable auxiliary button. Siren shutoff con-

Auxiliary

Instant

 

 

 

1, 2, 3

 

 

firms CS report.

 

 

 

 

 

 

 

08

Special Intrusion

Special belongings, such as gun cabinets and wall

Police

Instant

 

1, 2, 3

 

 

safes.

 

 

 

 

 

 

 

09

Special Intrusion

Special belongings, such as gun cabinets and wall

Police

Standard

 

1, 2, 3

 

 

safes.

 

 

 

 

 

 

 

10

Entry/Exit Delay

Entry and exit doors that require a standard delay

Police

Standard

2, 3

 

 

time.

 

 

 

 

 

 

 

11

Entry/Exit Delay

Garage doors and entrances that require an extended

Police

Extended

2, 3

 

 

delay time. *

 

 

 

 

 

 

 

12

Entry/Exit Delay

Driveway gates and entrances that require a twice

Police

Twice

2, 3

 

 

extended delay time. *

 

Extended

 

 

 

 

 

13

Instant Perimeter

Exterior doors and windows.

Police

Instant

2, 3

 

 

 

 

 

 

 

 

 

 

14

Instant Interior

Interior doors.

Police

Follower

 

2, 3

 

 

 

 

 

 

 

 

 

 

15

Instant Interior

Interior PIR motion sensors. *

Police

Follower

 

 

2, 3

 

 

 

 

 

 

 

 

 

 

16

Instant Interior

Interior doors.

Police

Follower

 

3

 

 

 

 

 

 

 

 

 

 

17

Instant Interior

PIR motion sensors. *

Police

Follower

 

 

3

 

 

 

 

 

 

 

 

 

 

18

Instant Interior

PIR motion sensors subject to false alarms. * †

Police

Follower

 

 

3

 

 

 

 

 

 

 

 

 

 

19

Delayed Interior

Interior doors that initiate a delay before going into

Police

Standard

 

3

 

 

alarm. *

 

 

 

 

 

 

 

20

Delayed Interior

PIR motion sensors that initiate a delay before going

Police

Standard

 

 

3

 

 

into alarm. *

 

 

 

 

 

 

 

21

Local Instant

24-hour local alarm zone protecting anything that

Police

Instant

 

 

1, 2, 3

 

Interior

opens and closes.

 

 

 

 

 

 

 

22

Local Delayed

Same as group 21, plus activation initiates a delay

Police

Standard

 

 

1, 2, 3

 

Interior

before going into alarm.

 

 

 

 

 

 

 

23

Local Instant

24-hour local alarm zone protecting anything that

Auxiliary

Instant

 

 

1, 2, 3

 

Auxiliary

opens and closes. ‡

 

 

 

 

 

 

 

24

Local Instant

24-hour local alarm zone protecting anything that

Auxiliary

Instant

 

 

1, 2, 3

 

Auxiliary

opens and closes. Sirens shut off at restoral. *

 

 

 

 

 

 

 

25

Local Special

Notify the user when a door is opened. Sounds emit

Special

Instant

 

 

 

1, 2, 3

 

Chime

from a local annunciator. *

Chime

 

 

 

 

 

 

Concord Ultra

82

Page 87
Image 87
GE 60-960-95 installation instructions Appendix B Reference Tables