3.4 CABLE REQUIREMENTS

 

 

 

 

 

 

 

 

EQUIPMENT

CABLE

AWG

MAX FEET

MAX METERS

 

 

 

 

 

DIGITAL KEYSET

1 PR. TWISTED

24

1300

400

 

 

 

 

 

ADD-ON MODULE

1 PR. TWISTED

24

1300

400

 

 

 

 

 

SINGLE LINE STATION

1 PR. TWISTED

24

3000

1 KM

 

 

 

 

 

DOOR PHONE

2 PR. TWISTED

24

330*

100

 

 

 

 

 

*This the maximum distance a door phone can be from the DPIM. The DPIM can be up to 900 cable feet from the KSU. The total distance must not exceed 1230 feet.

3.5 RINGS AND TONES3.5.1 RING CYCLES

The OfficeServ 7200 provides the trunk line rings, station rings, door rings, and alarm rings. The ON/OFF cycle of each ring is shown in the table below (it is different according to the country, and can be modified by MMC pro- gramming).

3.5.1a SYSTEM RING CYCLES

 

 

RINGON/OFF CYCLE

 

 

TRUNK LINE RING

1000/2000 ms

 

 

STATION RING

400/200/400/3000 ms

 

 

DOOR RING

400/200/400/200/400/2000 ms

 

 

ALARM RING

400/200/400/200/400/200/400/1000 ms

 

 

Note: The ON/OFF cycle can be adjusted by changing the values of the system database.

3.5.2 RING

The output voltage and frequency of the ring signals in the OfficeServ 7200 are as follows:

Output voltage: 75 Vrms Square Wave (Built in SLI)

Frequency: 20 or 25 Hz

The OfficeServ 7200 provides the users with various tones to notify the users of the status of functional opera- tions. The ON/OFF cycles of currently specified tones are shown in the table on the next page.