1.3 MAXIMUM DEVICE QUANTITIES
DEVICE TYPEMAXIMUMNOTES

 

 

 

Physical Ports

192

In a 2 cabinet system

 

 

 

Stations

160*

*Maximum number of stations without

Digital

any trunks. Limited by the number of

160*

Analog

available universal slots and power supply

120

IP

units.

 

 

 

 

Trunks

144*

*Maximum number of trunks without any

Analog

80

stations. Limited by the number of

- Loop Start

80

available universal slots.

Digital

96

 

- T1/PRI

96/92

Maximum 4 per system.

 

 

 

Networking Nodes

 

 

Using QSIG over PRI

5

Uses available T1/PRI card slots.

Using QSIG over IP

15

Limited by IP Address Table, MMC 820.

 

 

 

 

 

Required to connect an IP phone to a

Media Gateway Ports

160

TDM device including paging and

background music and ports used for net-

 

 

 

 

working or trunking.

 

 

 

Conferencing Circuits

 

 

5 Party Add-On

6

 

Unsupervised

6

Six Conference Circuits to be shared by all

Barge-In

6

of these features.

Call Record

6

 

AME

6

 

 

 

 

Common Resources

 

 

DTMF Receivers

16

4 on MCP plus 12 on optional MFM board

DTMF Senders

32

All on MCP

Analog Caller ID Senders/Receivers

14

Optional RCM2 daughter board

External Music On Hold (MOH)

2

Requires CPE and optional MIS

 

 

 

Paging

 

 

Audio Output

1

1 on MIS daughter card.

Internal Zones

5

(99 members each zone)

External Zones

2

Requires customer provided equipment.

 

 

 

Voice Mail / Auto Attendant Ports

12

System can have only one SVMi-20E card

installed. Any port can be shared as

SVMi-20E

 

 

AA/VM or dedicated to AA or VM.

 

 

 

 

 

NOTE: Installing some combinations of these cards will reduce the maximum capacities listed above.

1.5