Installation space for floor type indoor unit

ffTo minimize the waste of space due to installation, install the indoor unit as shown in below figure.

-- Top view ❋❋ After completing the installation, remove the protection vinyl.

50cm or more

Protection vinyl

CAUTION

Installation space for floor type indoor unitPiping length for indoor/outdoor unit installation (Be careful of static electricity).

❋❋ After completing the installation, remove the protective filament film on the product.

• Make sure that there are no obstacles (such as curtains etc.) blocking air inlets of the indoor unit.

• Clear space on the right side of the indoor unit for possible filter maintenance in the future.

Piping length for indoor/outdoor unit installation

Noobstaclemore or 1m

Maximum

6m or

less

allowable piping

 

elevation 10m

 

Install S-trap for every 6m

Maximum allowable piping length 20m or less

ffRefer to illustration on the left for maximum allowable piping length and elevation.

ffSince product performance and lifespan may decrease as piping length becomes longer, try to minimize the piping length but make sure it is over 5m.

ffSelect the installation location where you can keep the piping bending to maximum 10 spots.

ffStated cooling performance is based on product with 5m piping.

• One S-trap must be installed on the low pressure

CAUTION pipe up to 6m of piping elevation. For piping elevation that exceeds 6m, install S-trap every

6m.

or less

 

30cm or more

or

 

 

 

 

Outdoor unit

30cm

 

 

more

30cm or

Air guide

 

 

(Not provided by

 

 

more

 

 

manufacturer )

50cm

 

 

or

 

 

 

more

more

 

 

 

 

or

 

 

 

60cm

 

 

Outdoor

 

 

unit leg

 

 

 

Rubber leg

20cm or more

 

 

 

 

Spare space for piping

When air guide needs to be installed to prevent the warm discharge air from disturbing the pedestrian, refer to the illustration on the right side for installation.