Samsung AF28FSZDAWKNMG, AF28FSSDAWKNFA, AF27FSSDAWKNER Indoor/outdoor unit installation diagram

Models: AF28FSSDADFNMG AF28FSSDADFNFA

1 54
Download 54 pages 46 Kb
Page 41
Image 41
Indoor/outdoor unit installation diagram

Indoor/outdoor unit installation diagram

Connecting the outdoor unit drain hose

ffPush the drain plug into the drain hose connection part as far as possible.

ffPush the drain hose into the drain plug as far as possible and check

Drain hose

to make sure water is drained properly.

connection part

 

• Water may leak if the drain hose is not connected properly.

 

CAUTION

Therefore, check for water leakage after the installation.

 

 

 

• Frost may form during heating operation. Make sure to check for proper drainage in defrost operation.

• Do not install on the place where bottom part of the outdoor unit is at lower level than the drain hose.

• When installing the drain hose for draining the outdoor unit condensation of the cooling/heating product, make sure to install it so that it allows natural draining.

• When fixing the product, make sure that the product is level.

-- When the product is not in level, noise may generate due to vibration.

-- When the product is not in level, condensation that forms during heating operation may overflow instead of being drained through the drain hose and cause property damage.

Bottom part of the outdoor unit

Connecting the outdoor unit drain hoseManual background Drain plug

Drain hose connection part

Outdoor

Indoor

 

Pipe

 

Drain hose

40

칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A(5).indd 40

2014-03-12 오전 9:33:12

Page 41
Image 41
Samsung AF28FSZDAWKNMG, AF28FSSDAWKNFA Indoor/outdoor unit installation diagram, Connecting the outdoor unit drain hose