Drilling a hole and fixing the indoor unit

ffDrill a hole with diameter of 60~65mm towards the outside.

fIfthe indoor unit is installed on unstable ground, it may be shaken by an external force or children, and eventually get knocked down. To prevent these accidents, you must fix the top or back of the indoor unit tightly with fixing brackets.

200mm

ø60~65mm

150mm or less

 

Connecting pipes

• When installing, make sure there is no leakage. When recovering the refrigerant, stop the compressor first

WARNING before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant

cycle abnormally high. It may cause explosion and injury.

Installation procedure

1.Slightly hit the hole, for piping connection, with your hands or hammer.