4-2-1. If the trouble is detected by self-diagnosis

TROUBLESHOOTING

4-2-1. If the trouble is detected by self-diagnosis

-The error of sensor will be displayed on the front of display.

when the error of sensor is detected at initial power ON, the appliance will not operated and display of abnormal sensor part will blink.

-The appliance will not stop operating when the error of sensor is detected during operation of the appliance. But normal freezing might be not operated if the appliance is operated by the emergency operation mode. You would better to check the appliance according to the self-diagnosis of the manual.

1) If ICE Maker Sensor has trouble

ERROR Code

2¢ (-17¡ ) is recommended

38¢ (3¡ ) is recommended

DATA1.

Temperature table

**Measuring point of resistance value according to Sensor **

ICE MAKER : CN90#8 #4 measuring resistance value

** 0 : Short trouble /

: Open trouble

 

 

 

 

Refer to circuit diagram in the manual

 

Sensor MICOM/Connector number

 

 

 

ICE

Connector CN90#"4"(White) and

Maker

REG1 HEAT PCB common Ground

 

Voltage measured between 4.6V ~ 0.6V.

Measuring voltage of IC01 MICOM #78, CN90-"4"(White) and REG1, HEAT SINK from PCB typical Ground part are similar.

Check the measure on the SENSOR

MARKING #9(R901) due to the SMD MICOM

Checking method of ICE Maker Sensor resistance CN90# "8(Sky-blue) #4"(White)

- Compare the temperature table after the measure.

Start

Is MAIN PCB Connector

NO

CN90 inserted correctly?

 

 

 

 

 

 

 

 

 

YES

NO

Bad contact of connector/ insert correctly

 

Is ICE Maker Sensor

 

 

 

 

 

 

unit normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Replace the ICE Maker

 

 

 

 

 

 

 

 

 

 

Is the voltage between

NO(0.6V > Measurement < 4.6V)

MAIN PCB ConnectorCN90#4

 

 

 

 

 

(White) and REG1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

NO

Check the contact of PCB & Wire Terminal

 

 

Is input voltage of IC01

 

 

 

 

 

 

 

 

 

 

 

MICOM #78 normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Check the iced-solder, solder bridging,

 

 

 

 

 

 

 

 

disturbed solder.

 

No trouble with PCB and temperature sensor.

 

 

 

 

 

 

Recheck the bad contact of the connection.

 

 

 

 

 

 

 

 

 

 

 

 

Checking method of ICE Maker Sensor voltage

 

- Measure the voltage of Sensor Check Point #9(IC01 MICOM #78)

typical PCB Ground

or CN90#4(White) REG1, HEAT SINK.

- Compare the temperature table after the measure. Measuring

REG1 HEAT-SINK

voltage of CN90#4(White) REG1, HEAT SINK are below.

 