Samsung RF26XAERS, RF267AEBP Troubleshooting, If Ambient Sensor has trouble, Start, unit normal?

Models: RF267AEPN RF267AEXAA RF267AEWP RF267AERS RF26XAEXAA RF26XAE** RF26XAEPN RF26XAERS RF267AE** RF267AEBP

1 118
Download 118 pages 57.03 Kb
Page 62
Image 62
4) If Ambient Sensor has trouble

TROUBLESHOOTING

4) If Ambient Sensor has trouble

ERROR Code

2¢ (-17¡ ) is recommended

38¢ (3¡ ) is recommended

DATA1.

Temperature table

**Measuring point of resistance value according to Sensor **

Ambient : CN31#1 #4 measuring resistance value ** Placed in the right top table of upper hinge.

** 0 : Short trouble /

: Open trouble

 

 

 

 

Refer to circuit diagram in the manual

 

Sensor MICOM/Connector number

 

 

 

Ambient

Connector Cn31#1(Yellow) to REG1

HEAT-SINK PCB common Ground

 

Voltage measured between 4.6V ~ 0.6V.

Measuring voltage of IC01 MICOM #72,

CN31-"1"(Yellow) and REG1, HEAT SINK from

PCB typical Ground part are similar. Check the measure on the SENSOR MARKING

#7(R307) due to the SMD MICOM

Start

Is MAIN PCB

NO

 

 

 

Connector CN31 inserted

 

 

 

 

 

correctly?

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

NO

Bad contact of connector/ insert correctly

 

Is Ambient Sensor

 

 

 

 

 

 

unit normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Replace the temperature sensor

 

 

 

 

Is the voltage between

NO(0.6V > Measurement < 4.6V)

MAIN PCB Connector CN31#1(Yellow) and REG1,

 

 

 

 

 

HEAT SINK normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

NO

Check the contact of PCB & Wire Terminal correctly.

 

 

Is the input voltage of

 

 

 

 

 

 

 

 

 

 

 

IC01 MICOM #72 normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Check the iced-solder, solder bridging,

 

 

 

 

 

 

 

 

disturbed solder. Replace the PCB

 

No trouble with PCB and temperature sensor

 

 

 

 

 

 

Recheck the bad contact of the connection

 

 

 

 

 

 

 

 

 

 

 

 

Checking method of Ambient Sensor resistance CN31#1(Yellow) #4(Yellow)

-Compare the temperature table after the measure

Checking method of Ambient Sensor voltage

 

- Measure the voltage of Sensor Check Point #7

 

(IC01 MICOM #72) or CN31#1(Yellow) REG1, HEAT SINK.

typical PCB Ground

- Compare the temperature table after the measure. Measuring

voltage of CN31#1(Yellow) REG1, HEAT SINK are below.

REG1 HEAT-SINK

61

Page 62
Image 62
Samsung RF26XAERS, RF267AEBP Troubleshooting, If Ambient Sensor has trouble, Start, unit normal?, NO0.6V Measurement