Samsung RF26XAE**, RF267AEBP, RF267AE** Troubleshooting, If compressor does not operate, Start

Models: RF267AEPN RF267AEXAA RF267AEWP RF267AERS RF26XAEXAA RF26XAE** RF26XAEPN RF26XAERS RF267AE** RF267AEBP

1 118
Download 118 pages 57.03 Kb
Page 74
Image 74
4-2-7. If compressor does not operate

TROUBLESHOOTING

4-2-7. If compressor does not operate

Start

Did 7 mins pass after Compressor OFF ?

Refer to test function

Does compressor work

in the manual

with manual operation?

Check after

7minutes

Did buzzer of manual operation sound? (Check certainly after manual operation)

1)Replace MICOM

2)Replace PCB

1)Replace IC72 Driver IC(TD62083AP)

2)Replace PCB

Refer to circuit diagram in the manual

Is IC02 MICOM #8

High?(5V)

Is IC72 #15 about

0.8V?

Is CN71 connector

normal?

normal

Check bad contact of

connector

Is COMP ASS'Y

normal?

Normal (recheck)

Checking method of voltage PCB typical

Checking method of voltage

Ground CN1#3(Black) and

PCB typical Ground CN1#3(Black) and

1) IC02 MICOM #8 ; voltage High(5V 0.5V)

1) IC72 #15 : Voltage Low(0V)

IC02 MICOM #8, COMP operating

 

Replace COMP ASS'Y

typical PCB Ground CN1#3(Black)

73

Page 74
Image 74