Samsung RF26XAERS Troubleshooting, Start Are the all deforst heater normal?, Is defrost sensor by

Models: RF267AEPN RF267AEXAA RF267AEWP RF267AERS RF26XAEXAA RF26XAE** RF26XAEPN RF26XAERS RF267AE** RF267AEBP

1 118
Download 118 pages 57.03 Kb
Page 72
Image 72
Start

TROUBLESHOOTING

4-2-5. If defrost does not operate (F,R DEF Heater)

-If defrost has trouble, select the self-diagnostic function to detect the error of defrost heater before Power Off. (Check the function with the self-diagnostic function)

R DEF ERROR

F DEF ERROR

Is defrost sensor by **Measuring point of resistance value according to heater**

F-DEF(Ice Duct parallel) : CN70#7(Brown)

CN71#9

(Orange) measuring resistance value(55 ohm

7%)

R-DEF : CN70#5(White) N71#9(Orange)

 

measuring resistance value(110 ohm 7%)

 

** 0 : Short trouble /

: Open(bimetal, heater) trouble

Is power applied to **Measuring point of resistance value according to sensor **

Normal F-DEF : CN30#4 CN76#1 measuring resistance value Manual background R-DEF : CN30#8 CN76#1 measuring resistance value

** 0 : Short trouble /

: Open trouble

Resistance value of sensor according to temperature

Start

Are the all deforst

heater normal?

Checkthebimetal,heater disconnection,wiringconnectionetc.

86

(30

)

4.22

If you need the

68

(20

)

6.05

50

(10

)

8.87

temperature with detail,

32

(0

)

13.29

refer to DATA1.

14

(-10

)

20.42

temperature

-4

(-20

)

32.23

table

-22

(-30

)

52.41

 

Manual background **Measuring point of resistance value according to sensor **

Manual background F-DEF : CN30#4 CN76#1 measuring resistance value

Manual background R-DEF : CN30#8 CN76#1 measuring resistance value Manual background ** 0V: Short trouble / 5V: Open trouble

Is defrost sensor by

self-diagnostic normal?

Is the temperature of defrost sensor lower than 53.6 (12°C)?

Manual defrosting of fresh food

and freezer compartments

operate simultaneously.

Refertoself-diagnostic function in the manual

Replacethe applicablesensor

manual operation fora certaintime

Manual background If Energy Saver + Fridge key are pressed

Manual background simultaneously for 8 seconds and select any key. Manual background 4thtest mode(manual defrosting will be operated).

Recheck the applicable

sensor.

Reference If defrost sensor temperatures of fresh food and freezer compartments are higher than 50 (10 ), 53.6 (12 ) by the heating from heater, heating would be finished and will return to cooling operation after a pause.

Checking method of F,R DEF Heater resistance value Manual background

F DEF ; CN70#7(Brown)

CN71#9(Orange)

R DEF ; CN70#5(White)

CN71#9(Orange)

Manual background- Recheck if resistance values are different after the test

Manual background 1) F DEF Heater 2) R DEF Heater

Is power applied to

each defrost heaters?

Doesthesystemreturn tocoolingoperationafter heatingforspecifiedtime?

Normal

Isconnectionterminalof MAINPCBpartnormal?

Check bimetal, heater itself,

disconnection etc.

Replace failure Relay or

replace PCB ASS'Y

Repair connection terminal

71

Page 72
Image 72
Samsung RF26XAERS, RF267AEBP Troubleshooting, Start Are the all deforst heater normal?, Is defrost sensor by, Normal