Samsung RF26XAEXAA, RF267AEBP, RF267AE** Troubleshooting, unit normal?, NO0.6V Measurement

Models: RF267AEPN RF267AEXAA RF267AEWP RF267AERS RF26XAEXAA RF26XAE** RF26XAEPN RF26XAERS RF267AE** RF267AEBP

1 118
Download 118 pages 57.03 Kb
Page 65
Image 65
Ambient : CN31#3 CN76#1 Measure the resistance

TROUBLESHOOTING

7) If Ice Room Sensor has trouble

ERROR Code

2¢ (-17¡ ) is recommended

38¢ (3¡ ) is recommended

DATA1.

Temperature table

**Measuring point of resistance value according to Sensor **

Ambient : CN31#3 CN76#1 Measure the resistance

value

: Open trouble

** 0 : Short trouble /

 

Refer to the circuit diagram in this manual

 

Sensor MICOM/Connector number

Ice Room

Connector Cn31#3(Orange) to REG1

HEAT-SINK PCB common Ground

Voltage measured between 4.6V ~ 0.6V.

Measuring voltage of IC01 MICOM #77,

CN30-"4"(Orange) and REG1, HEAT SINK from PCB

typical Ground part are similar.

Check the measure on the SENSOR MARKING #8(R308) due to the SMD MICOM

Start

Is MAIN PCB

NO

 

 

 

ConnectorCN31 and CN76

 

 

 

 

 

inserted correctly?

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

NO

Bad contact of connector/ insert correctly

 

Is Ice Room Sensor

 

 

 

 

 

 

unit normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Replace temperature sensor

 

 

 

 

Is the voltage between

NO(0.6V > Measurement < 4.6V)

MAIN PCB Connector CN31#3 (Orange) and

 

 

 

 

 

REG1, HEAT SINK normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Check the contact of PCB & Wire

 

 

 

 

Is the input voltage of

NO

Terminal correctly.

 

 

 

 

 

 

 

 

 

 

 

 

IC01 MICOM #71 normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Check the iced-solder, solder bridging,

 

 

 

 

 

 

 

 

disturbed solder. Replace the PCB

 

No trouble with PCB and temperature sensor.

 

 

 

 

 

 

Check the bad connections.

 

 

 

 

 

 

 

 

 

 

 

 

Checking Mehod of Ice Room Sensor voltage CN31-”3”(Orange) CN76-”1” (Gray)

-Compare with the temperature table after measurement.

Checking method of Ice Room Sensor voltage

 

- Measure the voltage of Sensor Check Point #8

 

(IC01 MICOM #71) on PCB or CN31#3(Orange) REG1, HEAT SINK

typical PCB Ground

- Compare the temperature table after measurement. Measuring

voltage of CN31#3(Orange) REG1, HEAT SINK are as below

REG1 HEAT-SINK

64

Page 65
Image 65
Samsung RF26XAEXAA Troubleshooting, unit normal?, NO0.6V Measurement, Compare with the temperature table after measurement