TROUBLESHOOTING

10) If Tank Water Heater has trouble

ERROR Code

Measure the resistance between #6~#10 after CN79 connector

open 72ohm 7%

Start

Is MAIN PCB connector (CN79) inserted correctly?

YES

NO

Bad contact of connector/

MICOM

Initial

Heater off

Working

power On

heater

#6

3.5V~4.8V

3.5V~4.8V

0V

Is Tank Water Heater normal?(about72ohm)

Manual backgroundYES

Is the input voltage of

IC01 MICOM #6 normal?)

NO

NO

insert correctly

1) Wire connector

2) Replace Heater

Checking method of Tank Water Heater resistance CN78#5(Black) #4(Brown)

**: Open(wire disconnection, heater

disconnection) trouble 0 : Short trouble

Checking method of Tank Water Heater resistance CN79#6(Pink) #10(White)

**: Open(wire disconnection, heater

disconnection) trouble 0 : Short trouble

Manual backgroundYES

Normal(recheck)

1)Recheck the wire

2)Replace PCB MAIN