8) If Pantry Sensor has trouble

TROUBLESHOOTING

8) If Pantry Sensor has trouble

ERROR Code

2¢ (-17¡ ) is recommended

38¢ (3¡ ) is recommended

DATA1.

Temperature table

**Measuring point of resistance value according to Sensor **

Pantry : CN30#9 CN76#1 measuring resistance

 

value

: Open trouble

** 0 : Short trouble /

 

 

 

 

Refer to circuit diagram in the manual

 

Sensor MICOM/Connector number

 

 

 

Pantry

Connector Cn30#9(White-black) to REG1

HEAT-SINK PCB common Ground

 

Voltage measured between 4.6V ~ 0.6V.

Measuring voltage of IC01 MICOM #73,

CN30-"9"(White-black) and REG1, HEAT SINK from PCB typical Ground part are similar.

Check the measure on the SENSOR MARKING

#6(R314) due to the SMD MICOM

Start

Is MAIN PCB

NO

 

 

 

Connector CN30 and CN76 insert

 

 

 

 

 

correctly?

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

NO

Bad contact of connector/ insert correctly

 

Is Pantry Sensor

 

 

 

 

 

 

normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Replace temperature sensor

 

 

 

 

Is the voltage between

NO(0.6V > Measurement < 4.6V)

MAIN PCB Connector CN30#9 (White-black) and

 

 

 

 

 

REG1, HEAT SINK normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Check the contact of PCB & Wire

 

 

 

Is the input voltage of IC01

NO

Terminal correctly.

 

 

 

 

 

 

 

 

 

 

 

 

MICOM Pin #73 normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Check the iced-solder, solder bridging,

 

 

 

 

 

 

 

 

disturbed solder. Replace the PCB

 

No trouble with PCB and temperature sensor.

 

 

 

 

 

 

Recheck the bad contact of the connection.

 

 

 

 

 

 

 

 

 

 

 

 

Checking method of Pantry Sensor resistance CN30#9(White-black) CN76#1(Gray)

- Compare the temperature table after the measure

Checking method of Pantry Sensor voltage

- Measure the voltage of Sensor Check Point #6(IC01 MICOM #73) on PCB or CN30#9(White-black) REG1, HEAT SINK

- Compare the temperature table after measurement. Measuring voltage of CN30#9(White-black) REG1, HEAT SINK are as below

typical PCB Ground

REG1 HEAT-SINK

65