Samsung AD18B1C09, UD26B1C2, UD18B1C2, AD26B1C13 If the lamp is not flickering, check as follows

Models: AD26B1C13 AD18B1C09 UD18B1C2 UD26B1C2

1 37
Download 37 pages 43.39 Kb
Page 10
Image 10
If the lamp is not flickering, check as follows:

If the lamp is not flickering, check as follows:

A. Check the display part of indoor unit of each unit (A,B) after outdoor unit PCB switch S/W-A is on. A. Check the status of each unit indoor room select switch.

A. (Adjust the select switch suitable to the unit A, B.)

A. - A unit : STANDARD LED on, TIMER LED flickering

A. - B unit : STANDARD LED on, TIMER and NATURE LED flickering

A. - C unit : STANDARD LED on, TIMER and NATURE, POWER LED flickering (In case of triple split multi air conditioner)

UNIT

STANDARD

TIMER

NATURE

POWER

A

 

 

 

 

B

 

 

 

 

C

 

 

 

 

 

Lamp ON

Lamp OFF

Lamp Flasher

4.Check the test operation status by pressing the PCB switch

4.S/W-A and S/W-B of outdoor unit.

4.• Check the operation status by pushing the switch one at time.

4.• Perform the test operation only for the unit selected last.

4.• Check the pipe pressure and the other operation status during the test operation.

4.• Check items when the error occurs during the test operation (each unit)

-Check there is enough refrigerant.

-Check pipe connections.

9

Page 10
Image 10
Samsung AD18B1C09, UD26B1C2, UD18B1C2, AD26B1C13 service manual If the lamp is not flickering, check as follows