1)Troubleshooting procedure
Remove power cord and plug in again approx. 5 Seconds
Is operation lamp blinking?
YES
“ “ sound heard from the indoor unit when ON/OFF button on the remote control unit pushed?
NO
Voltage of battery less than 2.5V (Remote Control Unit)?
NO
LCD display status of REMOCON normal?
YES |
|
Transmission display lamp ( | ) blinking when |
ON/OFF button on the remote control unit pushed?
YES
Voltage at PIN #30 of Remocon Micom change?
YES
Voltage at collecter of Q601 or Q602 change?
YES
Voltage at pin #26 of micom (IC04) change (INDOOR UNIT)?
YES
NO
YES
YES
NO
NO
NO
NO
NO
Check as in the procedure “NO Power parts”.
Refer to page 11.
Normal
Replace battery.
LCD is faulty.
Replace button.
Micom is faulty.
Q601(C4375Y) or Q602(C1623Y) is faulty.
IR
Receiver module is faulty.
Micom (IC04) is faulty.
17