Samsung AD26B1C13, UD26B1C2, UD18B1C2, AD18B1C09 service manual 1-2“Pump down” Procedure

Models: AD26B1C13 AD18B1C09 UD18B1C2 UD26B1C2

1 37
Download 37 pages 43.39 Kb
Page 3
Image 3
1-2 “Pump down” Procedure

1-2 “Pump down” Procedure

1.Confirm that both the 2-way and 3-way valves are set to the open position.

(1)Remove the valve stem caps.

(2)Be sure to use a hexagonal wrench to operate the Gas side valve stems.

2.Operate the unit for 10 to 15 minutes.

3.Stop operation and wait for 3 minutes, then connect the charge set to the service port of the 3-way valve.

(1)Connect the charge hose with the push pin to the ser- vice port.

4.Air purging of the charge hose.

(1)Open the low-pressure valve on the charge set slightly to air purge from the charge hose.

5.Set the liquid side 2-way valve to the closed position.

6.Operate the air conditioner at the cooling cycle and stop operation immediately after setting the 3-way valve to the closed position when the gauge indicates 0 kg/cm2G.

If the unit can not be operated at the Cooling Mode(weater is rather cool), operate the unit at the Trubo Mode.

So that the unit can be operated.

7.Disconnect the charge set, and mount the both 3-way valve’s stem nuts and the service port cap.

2-Way Valve

Cap

3-Way Valve

Relocation of the air conditioner

Refer to this procedure when the unit is relocated.

1.Carry out the pump down procedure (refer to the details of ‘pump down’).

2.Remove the power cord.

3.Disconnect the assembly cable from the indoor and outdoor units.

4.Remove the flare nut connecting the indoor unit and the pipe.

At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering.

5.Disconnect the pipe connected to the out- door unit.

At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering.

6.Make sure you do not bend the connection pipes in the middle and store together with the cables.

7.Move the indoor and outdoor units to a new location.

8.Remove the mounting plate for the indoor unit and move it to a new location.

2

Page 3
Image 3
Samsung AD26B1C13, UD26B1C2, UD18B1C2, AD18B1C09 service manual 1-2“Pump down” Procedure