Samsung UD26B1C2, UD18B1C2, AD18B1C09, AD26B1C13 3-3-5When the outdoor unit fan does not operate

Models: AD26B1C13 AD18B1C09 UD18B1C2 UD26B1C2

1 37
Download 37 pages 43.39 Kb
Page 16
Image 16
3-3-5 When the outdoor unit fan does not operate

3-3-5 When the outdoor unit fan does not operate

1)Inspection items

(1)The outdoor unit fan motor operates only when the operating conditions are satisfied and is selected by the RY74(LOW) and PY75(HI) to rotate.

(2)Is the power voltage normal?

(3)Is the contact of outdoor unit fan motor (CN 73) good?

(4)Is the winding resistance of outdoor unit fan motor 58Ω at Hi side and 143Ω at low side?

(5)The outdoor unit fan motor operates with Hi at over 28°C and low at below 26°C during the cooling operation, and operates with Hi at below 14°C and low at over 15°C during the heating operation.

2) Inspection sequence

Apply the power to the outdoor unit and operate the indoor unit.

Is the indoor unit under operating conditions?

YES

Is it operating in the High speed?

NO

Is the voltage shown across the connector (1)↔(3) ((1)↔(5))

(the rating voltage ±10% range)?

NO

Is no. 11 ( 12) of IC 06 at low? (DC 0.7 V)

NO

Is pin no. 48(49) of IC 04 (MICOM) at High (DC 5 V)?

NO

Is the outdoor unit fan motor under the operating

conditions?

NO

NO

YES

YES

YES

YES

YES

Normal (operation off)

Normal

Check the winding resistance of outdoor unit fan

motor winding resistance → Replace

Contact bad of RY 74(Low), RY 75(High)

Replace

Defect of IC06 output

Replace

Defect of IC 04(MICOM) - replace the IC 04

or PCB ass’y

Normal

* Operating specification of the FAN of outdoor unit

(1)When the COMP is under the COMP ON condition during the cooling and heating operation, Hi or LOW operation is selected according to the temperature condition of outdoor room.

(2)When A room and B room are mixed to operate , it is always under low operation.

(3)Perform the comp ON/OFF control in the dry mode.

(4)When it is under the operation of anti-freezing, overload protection, defrost operation, it may be Low, high or Off.

(5)Hi = High speed, Low = Low speed

15

Page 16
Image 16
Samsung UD26B1C2, UD18B1C2, AD18B1C09, AD26B1C13 service manual 3-3-5When the outdoor unit fan does not operate