Recording settings

(User level: ID3)

 

 

 

 

 

 

CNORMAL REC MODE SET

It allows you to set the recording conditions of the normal recording and timer-controlled recording of the DVR.

The quality of the image depends on "image quality x recording rate". The higher frequency recording rate of the image, the higher the quality of the image. However, the amount of disk space needed to record these images is proportional to the quality of the image. Therefore, selecting a more quality image will result in shortened recording time.

1

 

2

 

3

5

4

 

1PICTURE QUALITY (Initial setting: ENHANCED)

It allows you to set the quality of the image recorded by the DVR.

Selecting a high quality image will result in shortened recording time.

Selections:

BASIC: Basic image quality

NORMAL: Normal image quality

ENHANCED: Enhanced image quality

FINE: Fine image quality

SUPER FINE: Super fine image quality

2AUDIO RECORDING (Initial setting: OFF) Simultaneous audio recording is possible for normal and timer-controlled recording.

ON: Simultaneous audio recording on

OFF: Audio recording off

Audio data is recorded in the same recording area as the images. Therefore, recording time is shortened.

If recording audio, set the recording rate between "1 - 50 FPS".

3REC RATE (Initial setting: 12.5 FPS)

To set the recording rate for normal recording. The letter "A" is displayed in front of the available recording rate.

Available settings:

50, 25, 16.67, 12.5, 8.333, 6.25, 5, 4.167, 3.571, 3.125, 2.778, 2.5, 2.273, 1.923, 1.667, 1.471, 1.316, 1.19, 1.087, 1, 0.5, 0.333, 0.25, 0.2, 0.1, 0.05, 0.033 (Unit: FPS)

About the Recording Rate

If multiple cameras are connected to the DVR, the recording rate of each channel varies according to the number of cameras connected.

If you use PROGRAM REC SET to program the recording rate of each individual camera, the recording rate cannot be set using NORMAL REC MODE SET.

Recording rates available are limited when pre-alarm recording or mirroring is set to "ON". Refer to the DVR manual for more information.

Use the TIMER SET to program the recording rate when using timer recording. (Refer to P28)

4REC PROGRAM GROUP (Initial setting: OFF) Recording conditions preset using PROGRAM REC SET (program number) can be selected. (Refer to P28)

Selections: OFF, P-1, P-2, P-3, P-4

OFF: Programed recording is not used.

A common recording rate for all the connected cameras is set using [REC RATE] on this screen.

P-1 - P-4:

The DVR records the images at the rate programed for each camera.

5Recording duration

Clicking [SAVE], displays, for your reference, a rough recording duration estimate according to the set recording rate.

English