Recording settings
1Display the <ALARM OPERATION SET> screen as explained in "Displaying the recording settings screen", and then turn the
The "OFF" indicator of ALARM RETRIGGER starts blinking.
MENU | <MAIN MENU> |
| 2.RECORD SET |
<RECORD SET> 8.ALARM OPERATION SET
(J)(S)
<ALARM OPERATION SET>
ALARM RETRIGGER | : ON |
MAIN MON. DISPLAY | : FULL |
ALARM PRIORITY | : LAST |
MON.2 DISPLAY | : NC |
2Turn the
The cursor moves to "MAIN MON. DISPLAY".
3Press the EXIT/OSD button when the settings are complete.
Operation returns to the normal screen.
EXIT/OSD
1Turn the
Selections: FULL/9/16/NC
The "FULL" indicator of MAIN MON. DISPLAY starts blinking.
|
| <ALARM OPERATION SET> | ||
|
| ALARM RETRIGGER | : OFF | |
(J) | (S) | MAIN MON. DISPLAY | : FULL | |
ALARM PRIORITY | : LAST | |||
|
| |||
|
| MON.2 DISPLAY | : NC |
2Turn the
Selections: LAST/FIRST/SWITCH
The "LAST" indicator of ALARM PRIORITY starts blinking.
3Turn the
The "NC" indicator of MON.2 DISPLAY starts blinking.
4Turn the
The cursor moves back to the ALARM RETRIGGER field.
5Press the EXIT/OSD button when the settings are complete.
Operation returns to the normal screen.
EXIT/OSD
English
bAlarm cancellation
•Forced cancellation of an alarm operation in progress Press the camera selection button of the channel with the alarm for about 3 seconds.
•Cancellation by a switch when alarm is detected Install a switch between the ALARM RESET and the C (ground) terminal of the terminal block on the rear panel, and turn on the switch when an alarm is detected.
ALARM RESET
C