General settings

FRS-485 settings

1 Connect the RS-485 terminal on the rear panel of

Figure 1 (Do not use telephone wires.)

the DVR with the system controller (Figure 1).

2 Display the <RS-485 SET> screen as explained in

(sold separately)

 

System controller

"Displaying the general settings screen", and then

A RS485 B

turn the S-dial clockwise. (P62)

 

The DATA SPEED "19200" indicator starts blinking.

MENU

<MAIN MENU>

 

 

3.GENERAL SET

 

<GENERAL SET>

 

6.RS-485 SET

(J)(S)

<RS-485

SET>

 

 

 

DATA SPEED

:

19200

STATUS INFO

:

ON

ALARM INFO

:

ON

ADDRESS

:

001

To other

A terminals

Straight cable

Cross cable

The DVR supports straight and cross-type cables.

Straight type:

A straight cable connects connector "A" to "A", and "B" to "B" of the RS-485 connectors.

Cross type:

A cross cable connects connector "A" with "B", and "B" with "A" on the RS-485 connectors.

3 Turn the J-dial to select the desired DATA SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(example: 9600), and then turn the S-dial twice

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

1

 

 

Pin number

Connector A

Connector B

clockwise.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selections: 2400/4800/9600/19200

 

 

 

 

 

 

1

Not used

Not used

 

 

 

 

 

 

 

 

 

 

 

2

Not used

Not used

The "OFF" indicator of STATUS INFO starts blinking.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

B

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS INFO :

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Not used

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Not used

Not used

4Repeat the procedure for selecting the desired settings for each item.

STATUS INFO

OFF: The status information will not be sent.

ON: The status information will be sent.

ALARM INFO

OFF: The alarm information will not be sent.

ON: The alarm information will be sent.

ADDRESS

The address should be between 000~127. The address is fixed, and it should match the address of the PTZ camera. Refer to the "List of

camera address" for more information. (P90) Refer to the system controller's instruction manual for more information about the control method.

5Press the EXIT/OSD button.

EXIT/OSD

Dome camera (sold separately)

Terminator switch settings

If multiple devices are connected, terminator settings are necessary at both ends. If the terminator settings are not correct, correct data will not be sent to the devices.

Set the terminator switch on both ends (first device and last device) to "ON", and set it to "OFF" on all other devices.

SW

ON

2 3

4

RS-485

RS-485

1

 

 

 

 

 

TERMINATE

TERMINATE

 

 

 

OFF ON

OFF ON

English

How to set 70