Interface (RS-485) specifications

b Data format

 

b Communication protocol

 

 

It is recommended that the exclusive controller is used for

Mode

Asynchronous

Character length

8 bits

operation as a protocol unique to our company (SANYO

Data transmission speed

2400, 4800, 9600, 19200bps

protocol) is used for this DVR. Consult the service center

Parity check

None

regarding the exclusive controller.

Stop bit

1 bit

 

bProtocol command table

The commands available through this DVR are as outlined in the table below.

 

Upper

 

 

 

 

 

 

 

 

 

level

0

1

2

3

4

5

6

7

Lower

 

 

 

 

 

 

 

 

 

 

level

 

 

 

 

 

 

 

 

 

0

 

 

 

 

0

 

 

TIMER

 

 

 

 

 

 

 

ON/OFF

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

1

 

 

 

 

2

 

 

 

 

2

 

 

 

 

3

 

 

 

 

3

 

SHIFT

SHIFT

 

4

 

 

 

 

4

 

SHIFT

SHIFT

MENU

5

 

 

 

 

5

 

 

SET+

 

 

 

 

 

 

 

/RP UP

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

6

 

 

SET-

 

 

 

 

 

 

 

/RP DOWN

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

7

 

 

 

 

8

 

 

 

 

8

 

 

 

 

9

 

 

 

 

9

 

 

SECURITY

 

 

 

 

 

 

 

LOCK ON

 

 

 

 

 

 

 

 

 

 

A

 

ACK

 

 

PLAY

REV PLAY/

 

 

 

 

 

 

SEARCH (DVR)

 

 

 

 

 

 

 

 

 

 

 

 

B

 

NAK

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

GROUP SET

 

D

 

 

 

 

 

 

 

GROUP

 

 

 

 

 

 

 

 

CHECK

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

GROUP

 

 

 

 

 

 

 

 

CLEAR

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

STOP

STILL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Upper

 

 

 

 

 

 

 

 

 

level

8

9

A

B

C

D

E

F

Lower

 

 

 

 

 

 

 

 

 

 

level

 

 

 

 

 

 

 

 

 

0

 

 

FULL 1

 

 

 

 

CLOCK

 

 

 

 

 

 

 

ADJUST

 

 

 

 

 

 

 

 

 

 

1

 

 

FULL 2

 

 

 

 

MENU RESET

 

2

 

MULTI (MPX)

FULL 3

 

 

 

 

 

 

3

 

QUAD (MPX)

FULL 4

 

 

 

 

 

 

4

 

PLUS1 (MPX)

FULL 5

 

 

 

 

 

 

5

 

ZOOM

FULL 6

 

 

 

 

 

 

 

(MPX/DVR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

FULL 7

 

 

 

 

 

 

7

 

SEQUENCE

FULL 8

 

 

 

 

 

 

 

(MPX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

MONITOR2

FULL 9

 

 

 

 

 

 

 

(MPX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

FULL 10

 

 

 

 

CLOCK

 

 

 

 

 

 

 

DOWNLOAD

 

 

 

 

 

 

 

 

 

 

A

 

ALARM RESET

FULL 11

 

 

REC

 

 

REC/DUB

 

 

 

 

 

REQUEST

 

 

 

 

 

 

 

 

 

B

 

 

FULL 12

FF/ALARM F

 

 

 

 

 

C

 

 

FULL 13

REW/ALARM R

 

 

 

 

 

D

 

COPY

FULL 14

 

 

 

 

 

RS-485

 

 

 

 

 

 

SEND START

 

 

 

 

 

 

 

 

 

E

 

EXIT/OSD

FULL 15

 

 

 

 

 

RS-485

 

 

 

 

 

 

RCV CMF.

 

 

 

 

 

 

 

 

 

F

 

 

FULL 16

 

STATUS LOG1

REC STOP

 

 

 

English