Connect the AC power cord to the projector and turn on the projector.
Turn off the projector and unplug the AC power cord. Let the projector cool for at least 45 minutes.
Remove the screw from the lamp cover and open the cover.
Loosen the two (2) screws that secure the lamp. Lift the lamp out of the projector by using the handle.

Maintenance and Cleaning

Lamp Replacement

When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the screen and LAMP REPLACE indicator lights yellow. Replace the lamp with a new one promptly. The timing when the LAMP REPLACE indicator should light is depending on the lamp mode.

WARNING:

TURN OFF THE UV LAMP BEFORE 

OPENING THE LAMP COVER

Note:

•The Lamp replacement icon will not appear when the Display function is set to “Off” (p.45), during “Freeze” (p.24), or “No show” (p.25).

Indicators

LAMP REPLACE

indicator

 

Lamp replacement icon

CAUTION

Allow a projector to cool for at least 45 minutes before you open the Lamp cover. The inside of the projector can become very hot.

CAUTION

For continued safety, replace with a lamp of the same type. Do not drop a lamp or touch a glass bulb! The glass can shatter and may cause injury.

Follow these steps to replace the lamp.

1

2

3

4 Replace the lamp with a new one and secure the two

(2)screws. Make sure that the lamp is set properly. Close the lamp cover and secure the screw.

5

6 Reset the lamp counter.

See “Lamp Replacement Counter” on the next page.

Note:

•When replacing the projection lamp, protect the infrared remote receiver with a soft cloth to avoid damaging it.

Lamp Cover

Screw

Screw Handle

Screw

Lamp

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information to the dealer.

Model No. of your projector

: PLC-XE50

Replacement Lamp Type No.

: POA-LMP121

 

 

(Service Parts No. 610 337 9937)

60

Page 60
Image 60
Sanyo PLC-XE50 owner manual Maintenance and Cleaning Lamp Replacement, Reset the lamp counter, Service Parts No 337