The projector is detecting abnormal condition.
| Indicators |
|
| |
POWER | WARNING | WARNING | LAMP | Projector Condition |
red/green | TEMP. | FILTER | REPLACE |
|
red | orange | yellow |
| |
|
| |||
|
|
|
|
|
|
|
|
| The temperature inside the projector is abnormally high. The projector |
|
|
|
| cannot be turned on. When the projector is cooled down enough and |
|
| ✽ | ✽ | the temperature returns to normal, the POWER indicator lights red |
|
| and the projector can be turned on. (The WARNING indicator keeps | ||
red |
|
|
| |
|
|
| blinking.) Check and clean the air filters. | |
|
|
|
| |
|
|
|
|
|
|
| ✽ | ✽ | The projector has been cooled down enough and the temperature |
|
| returns to normal. When turning on the projector, the WARNING | ||
red |
|
|
| indicator stops blinking. Check and clean the air filters. |
|
|
|
|
|
|
|
|
| The projector detects an abnormal condition and cannot be turned on. |
|
| ✽ | ✽ | Unplug the AC power cord and plug it again to turn on the projector. If |
|
| the projector is turned off again, unplug the AC power cord and contact | ||
|
|
|
| the dealer or the service center for service and checkup. Do not leave |
|
|
|
| the projector on. It may cause an electric shock or a fire hazard. |
✽ |
|
| ✽ | The Filter counter reached a set time. Clean or replace the filter as |
|
|
|
| soon as possible. |
|
|
|
|
|
LAMP REPLACE
When the projection lamp reaches the end of its life, the LAMP REPLACE indicator lights yellow. When this indicator lights yellow, replace the projection lamp with a new one promptly. Reset the lamp replacement counter after replacing the lamp. See pages