Check the indicators for projector condition.

Indicators

 

WARNING

LAMP

Projector Condition

POWER

REPLACE

 

 

red/green

red

yellow

 

 

 

 

 

 

 

 

 

The projector is off. (The AC power cord is unplugged.)

 

 

 

 

 

 

The projector is in stand-by mode. Press the POWER ON-OFF

 

 

button to turn on the projector.

 

 

 

 

 

 

 

 

 

The projector is operating normally.

 

 

 

 

 

 

 

The temperature inside the projector is abnormally high. The

 

 

 

projector cannot be turned on. When the projector is cooled down

 

 

enough and the temperature returns to normal, the POWER

 

 

 

indicator stops blinking and the projector can be turned on. (The

 

 

 

WARNING indicator keeps blinking.) Check and clean the filter.

 

 

 

 

 

 

 

The projector has been cooled down enough and the temperature

 

 

returns to normal. When turning on the projector, the WARNING

 

 

 

indicator stops blinking. Check and clean the air filter.

 

 

 

 

 

 

 

The projector is preparing for stand-by or the projection lamp is

 

 

being cooled down. The projector cannot be turned on until cooling

 

 

 

is completed and the POWER indicator stops blinking.

 

 

 

 

 

 

 

The projector detects an abnormal condition and cannot be turned

 

 

 

on. Unplug the AC power cord and plug it again to turn on the

 

 

projector. If the projector is turned off again, unplug the AC power

 

 

cord and contact the dealer or the service center for service and

 

 

 

 

 

 

checkup. Do not leave the projector on. It may cause an electric

 

 

 

shock or a fire hazard.

 

 

 

 

 

 

 

The projector is in the Power management mode.

 

 

 

 

 

 

The projector’s Network or Memory viewer function is in an

 

 

abnormal condition.

 

 

 

 

 

 

 

 

 

 

• • • green.

 

• • • red

• • • off

• • • blinks green.

 

• • • blinks red.

 

When the projection lamp reaches its end of life, the LAMP REPLACE indicator lights yellow. When this indicator lights yellow, replace the projection lamp with a new one promptly. Reset the lamp replacement counter after replacing the lamp. See pages 58-59.