NU4QG/NA3
OUTPUT TERMINALS
TAPE END OUT Terminal
•During recording, when the end of the tape is reached or when the tape counter reading indicates 7 hours 57 minutes or more, the output becomes 0V (Low).
•To reset the output, press the STOP or EJECT button.
•During autorepeat recording, when the end of the tape is reached, the output becomes 0V (Low) for about 2 seconds only.
Tape end or 7:57:00
Output reset
5V (H)
(Output impedance: 5.7 kΩ) 0V (L)
TAPE END OUT Terminal Output Setting
1Press the MENU button until the (SET UP 3) menu is displayed.
@@@@@@@<SET@UP@3>
*ALARM@MODE@@@@@@@Y1
*ALARM@SPEED@@@@@@8H
*ALARM@DURATION@@@20S
*VERTICAL@SYNC@@@@Y
*EXT@TIME@ADJ.@@@@01:00
*TAPE@IN@MODE@@@@@STOP
*TAPE@END@MODE@@@@REW
2Press the ] button until the “TAPE END OUT” setting is flashing.
3Press the l (or j) button, to select the desired output mode.
–3M . . . . . . . . The output becomes 0 V (Low) when the tape counter reaches “7:57:00” and/or when the tape reaches the end.
END . . . . . . . . The output becomes 0 V (Low) when the tape reaches the end.
4Press the PAUSE/SEARCH button to save the setting.
SW OUT Terminal
When recording, a pulse signal is output at the SW OUT terminal.
This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.
FIELD: 16.7 msec.
FRAME: 5 msec.
5V (H)
(Output impedance: 5.7 kΩ) 0V (L)
SW OUT Terminal Output Setting
1Press the MENU button until the (SET UP 4) menu is displayed.
@@@@@@@<SET@UP@4>
*SW@OUT
@@TIMING@@@@@@@@@@FIELD
@@FIELD@@@@@@@@@@@01
@@8H@@@@@@@@@@@@@@Y
*THREAD@CHECK@@@@@Y
*VIDEO@LOSS@@@@@@@N
*REC@SPEED@@@@@@@@N
*EJECT@SET
@@EJECT@MODE@@@@@@EJECT1
@@OPERATION@@@@@@@SLAVE
2Press the l (or j) button to set “FIELD” or “FRAME”, then press the ] button.
FIELD . . . . . . . 1 pulse is output after each set number of fields.
FRAME. . . . . . 1 pulse is output after each set number of frames.
3Press the l (or j) button to set the desired pulse signal interval, then press the ] button.
•If “TIMING” is set to FRAME (see step 2), “FRAME” will be indicated instead of “FIELD”.
Available settings are:
FIELD . . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field
FRAME. . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 frame
4Press the l (or j) button to set the desired “8H (or 6H)” mode.
•If the “TAPE” in the (SET UP 5) menu is set to
Y . . . . . . . . . . . When recording in
N. . . . . . . . . . . When recording in
5Press the PAUSE/SEARCH button to save the settings.
40 | English |