NU4QG/NA3
SETTINGS FOR RS485 TERMINALS USE
If the VCR is going to be controlled trough a connection to the RS485 terminals, be sure to first make the settings below.
NOTES:
•Can only be used with the optional
•When using the optional
1Press the MENU button until the (SET UP 6) menu is displayed.
°The “ADDRESS” setting is flashing.
@@@@@@@<SET@UP@6>
*RS485
@@ADDRESS@@@@@@@000
@@TERMINATE@@@@@N
@@DATA@SPEED@@@@19200
@@STATUS@INFO@@@Y
@@ALARM@INFO@@@@Y
2Press the l (or j) button to set the VCR address, then press the ] button.
5Press the l (or j) button to set the “STATUS INFO” setting, then press the ] button.
Y . . . . . . . . . . . The VCR status information (state information and warning state) are output at the RS485 terminal.
N. . . . . . . . . . . The state information is not output at the RS485 terminal. However, the warning state is output at the RS485 terminal.
6Press the l (or j) button to set the “ALARM INFO” setting.
Y . . . . . . . . . . . The VCR alarm information (alarm recording start and stop) and video loss information are output at the RS485 terminal.
N. . . . . . . . . . . The VCR alarm information (alarm recording start and stop) and video loss information are not output at the RS485 terminal.
NOTES:
•The address can be set between 000 and 127.
•Keep the button pressed and the setting will change rapidly.
3Press the l (or j) button to set the termination, then press the ] button.
N. . . . . . . . . . Not terminated Y . . . . . . . . . . Terminated
NOTE:
•The video loss information output (sent) will depend on the settings for “VIDEO LOSS” in the (SET UP 4) menu.
7Press the PAUSE/SEARCH button to save the settings.
4Press the l (or j) button to set the data transfer speed, then press the ] button.
19200 2400 4800 9600
38 | English |