NU4QG/NA3 (SRT-2400DC GB) Mon. Sept., 17/2001

SERIES RECORDING

Continous Loop Recording Setup

A minimum of 2 units are required for continuous loop recording.

Example with 2 VCRs.

Under loop recording when the recording finishes on the first unit, the new recording will start on the second unit. When the recording finishes on the second unit, recording will start on the first unit.

1The SERIES OUT/CLOCK OUT terminal of VCR No.2 and the SERIES IN terminal No.1 should be connected (See diagram).

2Set the following items as indicated.

Item

VCR No.1

VCR No.2

Cassette tape

Loaded

Loaded

 

 

 

Operation mode

Stop

Stop

 

 

 

“TAPE END MODE” (in

REW

REW

(SET UP 3) menu)

 

 

 

 

 

“SERIES REC IN” (in

Y (YES)

Y (YES)

(SET UP 3) menu)

 

 

 

 

 

“OUTPUT” (in (SET UP

SERIES

SERIES

5) menu)

 

 

 

 

 

Security lock

Canceled

Set

 

 

 

3Press the REC button on VCR No.1.

°Recording will start in series recording mode.

4Set the security lock on VCR No.1.

Loop recording connection (example with 2 VCRs)

Video camera

NOTES:

To avoid recording problems, the “TAPE END MODE” in (SET UP 3) menu should be set to “REW” for both units.

In loop recording mode, the tape will be re-recorded over. If you need to keep the recorded infomation, please eject the tape after recording is complete and insert a new tape.

Monitor TV

 

 

To

 

 

To

VCR No.1

 

VIDEO IN

VCR No.2

 

VIDEO IN

 

jack

 

jack

ALARM OUT/ ALARM IN/

SERIES OUT/ SERIES SW

EJECT

ALARM OUT/ ALARM IN/

SERIES OUT/ SERIES SW

EJECT

CLOCK OUT CLOCK IN COM

NON REC OUT IN OUT

OUT IN

CLOCK OUT CLOCK IN COM

NON REC OUT IN OUT

OUT IN

WARNING TAPE

 

 

WARNING TAPE

 

 

OUT END OUT COM

COM

 

OUT END OUT COM

COM

 

DC12V IN

 

DC12V IN

 

 

 

 

To

To COM

 

To COM

VIDEO OUT

terminal

To

terminal

jack

 

 

 

To

VIDEO OUT

To

 

jack

 

SERIES OUT

 

SERIES OUT

 

 

 

terminal

 

terminal

 

 

 

 

 

 

To

 

 

 

SERIES IN

 

To

 

terminal

 

 

 

 

SERIES IN

 

 

 

terminal

32

English

Page 33
Image 33
Sanyo SRT-2400DC Series Recording, Continous Loop Recording Setup, Loop recording connection example with 2 VCRs