Alarm Settings (ALARM)

8Use the joystick lever (xy) to select [DURATION] and use the lever (vw) to select the interval after which the next alarm becomes in effect.

When an alarm is detected, another alarm signal will not be output until the duration specified in this setting has passed.

Available settings: 5S, 10S, 15S, 20S, 30S, 45S, 1M, 2M, 3M, 4M, 5M (S: Second, M: Minute)

Memo: The interval setting for the next alarm to become in effect is applied to the external switch whose number is the same as the alarm input number. The alarm input from other external switches will be accepted.

When the alarm input is used as the external control input of the Day/Night function, “D/N” appears in the top right of the screen. In this case, settings other than [POLARITY] cannot be made.

When multiple alarm inputs are received simultaneously, the input whose alarm number is smaller precedes the others.

After completing setting, use the lever to move the cursor to [MENU] and select “BACK” or “END”.

B Setting the alarm output (ALARM OUT)

The ALARM OUT screen allows you to perform the alarm output settings for each alarm output number.

ALARM

 

 

ALARM IN

1

y

ALARM OUT

1

y

ALARM DISABLE

OFF

 

MOTION

OFF

 

ALARM DISPLAY

OFF

 

PRESET

OFF

 

MENU

BACK

 

1Use the joystick lever (xy) to select [ALARM OUT], use the lever (vw) to select an alarm output number (1- 2), and press the [ENTER] button.

The ALARM OUT screen appears.

ALARM OUT 1

 

 

 

OUTPUT

ON

POLARITY

NO

ALARM TIME

5S

PRESET

OFF

MENU

BACK

2Use the joystick lever (xy) to select [OUTPUT] and use the lever (vw) to select an alarm output option.

Available settings:

OFF: Does not output the alarm signal.

ON: Outputs the alarm signal.

REMOTE: Outputs the alarm signal by remote operation. (This option is available only when [ALARM OUT] is set to “2”.)

When selecting “REMOTE”, “MANU” is available for [ALARM TIME] enabling the manual operation of the alarm output.

When selecting “REMOTE”, the alarm signal will not be output automatically even when the alarm is detected.

3Use the joystick lever (xy) to select [POLARITY] and use the lever (vw) to select the polarity for the alarm output signal.

Available settings:

NO (Normal Open):

Normally open so closed condition is detected as output.

NC (Normal Close):

Normally closed so open condition is detected as output.

4Use the joystick lever (xy) to select [ALARM TIME] and use the lever (vw) to select a duration for which the alarm signal is output.

The connected devices such as recorder, alarm buzzer and warning lamp will operate for the duration you have specified.

Available settings: 2S, 5S, 10S, 15S, 20S, 30S, 45S, 1M, 2M, 3M, 4M, 5M, MANU

(S: Second, M: Minute)

Memo: “MANU” appears only when “REMOTE” is selected for [OUTPUT] in step 2.

After completing setting, use the lever to move the cursor to [MENU] and select “BACK” or “END”.

The alarm output duration for remote operation

The alarm output duration when using remote operation depends on the setting for [ALARM TIME].

When selecting the value between “2S” and “5M”: Outputs the alarm for the duration you have specified.

When selecting “MANU”:

Controls the alarm output duration by the AUX6 operation (ON/OFF) from external device.

While the alarm is output using remote operation, normal alarm output cannot be used.

40