Alarm Settings (ALARM)

Setting the alarm signal output

Set the alarm output options for the alarm detection in the surveillance area (AREA 1 - 4).

After returning to the MOTION ZONE screen, perform the following procedure.

MOTION ZONE

 

AREA 1

OFF

AREA 2

OFF

AREA 3

OFF

AREA 4

OFF

SENSITIVITY

SET y

ALARM OUT

OFF

LINE OUT

OFF

DURATION

5S

PRESET

OFF

MENU

BACK

1Use the joystick lever (xy) to select [ALARM OUT] and use the lever (vw) to select an alarm output terminal.

Available settings:

OFF: Does not output the alarm signal.

1: Uses the output terminal 1.

2: Uses the output terminal 2.

2Use the joystick lever (xy) to select [LINE OUT] and use the lever (vw) to determine whether the alarm signal is output to the connection line with the system controller.

Available settings:

OFF: Does not output the alarm signal to the connection line.

ON: Outputs the alarm signal to the connection line.

3Use the joystick lever (xy) to select [DURATION] and use the lever (vw) to select the interval after which the next alarm becomes in effect.

Available settings: 5S, 10S, 15S, 20S, 30S, 45S, 1M, 2M, 3M, 4M, 5M (S: Second, M: Minute)

After completing setting, use the lever to move the cursor to [MENU] and select “BACK” or “END”.

Setting the alarm information display

E (ALARM DISPLAY)

When the alarm is detected, the preset number and the camera ID on the screen flash notifying that the alarm is detected.

Monitor display legend

001 CAM1 FLOOR

 

ALARM

 

 

ALARM

IN

1

y

ALARM

OUT

1

y

ALARM

DISABLE

ON

 

TIME

 

1M

 

MOTION

 

PRESET

ALARM

DISPLAY

ON

 

TIME

 

5S

 

PRESET

 

OFF

 

MENU

 

BACK

 

1Use the joystick lever (xy) to select [ALARM DISPLAY] and use the lever (vw) to select “ON/OFF”.

Available settings:

OFF: The alarm information does not flash.

ON: The alarm information flashes.

([TIME] appears under [ALARM DISPLAY].)

2When “ON” is selected, use the joystick lever (xy) to select [TIME], and use the lever (vw) to select the duration for which the alarm information is flashing.

Available settings: 5S, 10S, 15S, 20S, 30S, 45S, 1M, 2M, 3M, 4M, 5M (S: Second, M: Minute)

After completing setting, use the lever to move the cursor to [MENU] and select “BACK” or “END”.

43