1. General

1. General

This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instruc- tions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning.

1-1. Tools Required for Installation (not supplied)

1.

Standard screwdriver

6.

Sabre saw or key hole saw

11.

Tube cutter

2.

Phillips head screwdriver

7.

Hacksaw

12.

Tube flaring tool

3.

Knife or wire stripper

8.

Core bits

13.

Torque wrench

4.

Tape measure

9.

Hammer

14.

Adjustable wrench

5.

Carpenter’s level

10.

Drill

15.

Reamer (for deburring)

1-2. Accessories Supplied with Unit Table 1

Parts

Figure

Q’ty

Remarks

Parts

Figure

Q’ty

Remarks

Washer

 

8

For temporarily

Truss head screw

3/16

13/32"

 

For full-scale

 

suspending indoor

4

installation

 

(5

10mm)

 

 

 

unit from ceiling

 

 

diagram

 

 

 

 

 

 

 

 

Flare

1/8"(T3)

2

For wide /

Drain hose

 

 

 

 

For unit & PVC

narrow tube

 

 

 

1

insulation

set

 

 

 

tube connection

3/16"(T5)

connection

 

5-1/2"(L140)

 

 

 

 

 

 

 

 

2

For wide /

Hose band

 

 

 

 

For drain hose

Insulation tape

 

narrow tube /

 

 

 

2

3/32"(T2)

 

 

 

connection

 

 

flare nut connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

For flare / drain

Tapping screw

Truss-head Phillips

2

 

Vinyl tie

 

insulating

5/32 5/8"

 

 

 

 

 

connection

 

(4 16mm)

 

 

 

Drain hose

 

1

For drain tube

Truss head screw

5/32

15/32"

4

 

insulation

13/32"(T10)

connection

(4

12mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Packed in the

 

 

 

 

 

 

 

 

 

Remote

 

1

 

 

 

 

 

 

ceiling panel

control unit

 

 

Special screw

3/16

1-9/16"

4

 

 

 

 

 

 

 

 

 

 

 

 

Remote control

 

 

 

 

(5

40mm)

 

 

 

1

 

 

 

 

 

 

 

unit holder

 

 

 

 

 

 

 

 

 

 

 

Use M10 or 3/8" for suspension bolts.

 

 

 

 

 

 

AAA alkaline

 

2

 

Suspension bolts and nuts (locally purchased)

 

 

 

 

 

 

 

 

battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full-scale

 

 

Printed on

 

 

 

 

 

 

installation

 

1

 

 

 

 

 

 

 

container box

 

 

 

 

 

 

diagram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-3. Optional Copper Tubing Kit

Copper tubing for connecting the outdoor unit to the indoor unit is available in kits which contain the narrow and wide tub- ing, fittings and insulation. Consult your nearest sales outlet or air conditioning workshop.

1-4. Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately from a local source, you will need:

1.Deoxidized annealed copper tube for refrigerant tubing as detailed in Table 2.

Cut each tube to the appropriate lengths 1' to 1'4" (30 cm to 40 cm) to dampen vibration between units.

2.Foamed polyethylene insulation for the specified copper tubes as required to precise length of tubing. Wall thickness of the insulation should be not less than 5/16" (8 mm).

3.Use insulated copper wire for field wiring. Wire size varies with the total length of wiring. Refer to 3-7. Wiring Instruc- tions for details.

Table 2

Model

Narrow Tube

Wide Tube

 

 

 

 

Outer Dia.

Thickness

Outer Dia.

Thickness

 

 

 

 

 

 

XMHS0972/1272

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

 

 

 

 

 

XHS1872

1/4" (6.35 mm)

0.0314" (0.8 mm)

1/2" (12.70 mm)

0.0314" (0.8 mm)

 

 

 

 

 

CAUTION

Check local electrical codes and regulations before obtaining wire. Also, check any specified instructions or limitations.