 HIGH POWER

 NIGHT SETBACK HIGH POWER

This function acts to raise the power but keeps the AC system in the same operating mode.

This function is set with the HIGH POWER button on the remote controller.

(It can be set regardless of the temperature and fan speed settings.)

 COOL and DRY modes HIGH POWER operation from remote controller The unit operates at maximum output for 30 minutes, regardless of the desired temperature.

The fan speed is 1 step above "High."

Frequency

MAX

 Lamp colors NIGHT SETBACK

When NIGHT SETBACK operation is set, the temperature and fan speed settings will be adjusted automatically to allow comfortable sleep.

When NIGHT SETBACK operation is set, "OPERATION lamp mark" appears on the remote controller. The main unit display lamp also becomes dimmer.

TIMER lamp COOL and DRY modes

When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2°F(1°C) when 30 minutes have passed after the selection was made, and then another 2°F(1°C) after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed.

0

Time

Setting temperature

2°F(1°C)

NOTE

30 min. 5 min.

Start End

Press the NIGHT SETBACK button

2°F(1°C)

 

 

30 min.

30 min.

Time

When HIGH POWER operation ends, the unit operates at low Hz for 5 minutes, regardless of the thermostat OFF conditions. When in DRY mode, operation is in the cooling zone.

HIGH POWER lamp Lamp colors

OPERATION lamp

 

HEAT operation

Red

DRY operation

Orange

COOL operation

Green

FAN operation

Green

DEFROSTING operation

Red and Orange

OPERATION lamp

alternately

Green

TIMER lamp

Green

HIGH POWER lamp

Green

 Timer backup Timer backup

Operation stops if there are no operator controls for 25 hours or longer after unit operation switched from OFF to ON by use of ON timer operation.

 HEAT mode HEAT mode

When the night setback mode is selected, the air conditioner automatically lowers the temperature setting 4°F(2°C) when 30 minutes have passed after the selection was made, and then another 4°F(2°C) after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle heating is needed.

Setting

 

4°F(2°C)

 

temperature

 

 

4°F(2°C)

 

 

 

Press the NIGHT

30 min.

30 min.

Time

SETBACK button

 

 

 