Section 4. Programming Reference

Print Quantity

Command Structure

<ESC>Qaaaaaa

 

aaaaaa =

Total number of labels to print (1-999999)

 

Example:

<ESC>Q500

 

Placement:

Just preceding <ESC>Z, unless <ESC>NUL exists, then

 

 

preceding that. This command must be present in every

 

 

print job.

 

Default:

None

Command Function

To specify the total number of labels to print for a given print job.

Input to Printer

<ESC>A

 

 

<ESC>H0100<ESC>V0100<ESC>WB1M-8400RV

 

<ESC>Q3

 

 

<ESC>Z

 

Printer Output

Three labels containing the data “M-8400RV” wll be printed.

Special Notes

1. To pause during a print job, you must press the LINE key on the

 

Operator Panel.

2. To cancel a print job, you must turn off the printer, or you may send the <CAN> code if using the Bi-Com mode. Multi-Buffer jobs can be cleared with the <ESC>* Clear Print Job(s) and Memory command (see Page 4-29).

3. When used with the <ESC>F Sequential Numbering command (see Page 4-72, the Print Quantity value should be equal to the total number of labels to be printed.

4. If you do not specify a Print Quantity, the printer will not print a label.

5. For this command, leading zeroes do not have to be entered. The command Q1 is equivalent to Q000001.

SATO M-8400RV

9001041 Rev. D

Page 4-61

Page 123
Image 123
SATO M-8400RV manual Print Quantity, Command Structure ESCQaaaaaa